吸烟者间质性肺异常的客观识别与量化
本研究在COPD遗传流行病学研究(Genetic Epidemiology of COPD study)2257例吸烟者的CT扫描中,开发并测试了一种全自动图像处理工具,该工具利用局部直方图分析联合胸膜表面距离来检测与间质性肺异常一致的影像特征。工具检测间质性肺异常的敏感度为87.8%、特异度为57.5%,c统计量为0.82;检测纤维化实质异常亚型的敏感度为100%、特异度为56.7%,c统计量为0.89。结论认为该全自动工具能以中等敏感度和特异度识别具有间质性肺异常的吸烟者。
要点
- 全自动工具检测间质性肺异常的敏感度为87.8%、特异度为57.5%,c统计量为0.82。
- 检测纤维化实质异常亚型的敏感度为100%、特异度为56.7%,c统计量为0.89。
- 工具基于局部直方图分析联合胸膜表面距离,客观识别CT上的间质性异常影像特征。
核心结论
- 在吸烟者中,一种全自动图像处理工具能以中等敏感度和特异度识别具有间质性肺异常的个体。
研究设计与样本
- 研究基于COPD遗传流行病学研究(Genetic Epidemiology of COPD study)这一纵向观察性研究中2257例吸烟者的CT扫描,开发并测试了一种利用局部直方图分析联合胸膜表面距离的全自动图像处理工具,以视觉识别的间质性肺异常存在与否为参考标准确定工具的敏感度和特异度。
诊断标准与关键数值
- 工具检测间质性肺异常的敏感度为87.8%、特异度为57.5%,c统计量为0.82。
- 工具检测视觉亚型纤维化实质异常的敏感度为100%、特异度为56.7%,c统计量为0.89。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: Previous investigation suggests that visually detected interstitial changes in the lung parenchyma of smokers are highly clinically relevant and predict outcomes, including death. Visual subjective analysis to detect these changes is time-consuming, insensitive to subtle changes, and requires training to enhance reproducibility. Objective detection of such changes could provide a method of disease identification without these limitations. The goal of this study was to develop and test a fully automated image processing tool to objectively identify radiographic features associated with interstitial abnormalities in the computed tomography scans of a large cohort of smokers.
MATERIALS AND METHODS: An automated tool that uses local histogram analysis combined with distance from the pleural surface was used to detect radiographic features consistent with interstitial lung abnormalities in computed tomography scans from 2257 individuals from the Genetic Epidemiology of COPD study, a longitudinal observational study of smokers. The sensitivity and specificity of this tool was determined based on its ability to detect the visually identified presence of these abnormalities.
RESULTS: The tool had a sensitivity of 87.8% and a specificity of 57.5% for the detection of interstitial lung abnormalities, with a c-statistic of 0.82, and was 100% sensitive and 56.7% specific for the detection of the visual subtype of interstitial abnormalities called fibrotic parenchymal abnormalities, with a c-statistic of 0.89.
CONCLUSIONS: In smokers, a fully automated image processing tool is able to identify those individuals who have interstitial lung abnormalities with moderate sensitivity and specificity.
引用
- Ash SY, Harmouche R, Ross JC, et al. The Objective Identification and Quantification of Interstitial Lung Abnormalities in Smokers. Acad Radiol. 2016. PMID: 27989445. doi:10.1016/j.acra.2016.08.023
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。