3T MRI改善常见颞骨病变成像:小结构受益于小视野
本研究在3T MRI上比较标准SPACE与分辨率优化的pTX-SPACE序列,二者扫描时间相同,共34例患者。pTX-SPACE改善了前庭神经鞘瘤、迷路内神经鞘瘤及前庭神经鞘瘤切除术后等病变的边缘显示和检出,但信噪比与对比噪声比显著降低;对迷路炎无优势。
要点
- pTX-SPACE在相同扫描时间下提高了前庭神经鞘瘤和迷路内神经鞘瘤的边缘显示与检出。
- pTX-SPACE对前庭神经鞘瘤切除术后耳蜗神经与面神经的区分及创伤后改变检出有改善。
- pTX-SPACE的信噪比和对比噪声比显著低于标准SPACE,迷路炎检出未优于标准SPACE。
核心结论
- pTX-SPACE显著提高颞骨病变的检出,尤其是前庭神经鞘瘤、迷路内神经鞘瘤和前庭神经鞘瘤切除术后。
研究设计与样本
- 在3T MRI上对34例患者行标准SPACE与分辨率优化的pTX-SPACE序列检查,比较信噪比、对比噪声比和图像质量。
关键影像表现/征象
- pTX-SPACE上前庭神经鞘瘤边缘界定和瘤内模式改善,与蜗轴区分更清楚。
- pTX-SPACE上迷路内神经鞘瘤边缘界定、与螺旋板分离及耳蜗转内检出改善。
- pTX-SPACE上内耳畸形、创伤后改变及前庭神经鞘瘤切除术后耳蜗神经与面神经区分检出改善。
- 迷路炎中pTX-SPACE不优于标准SPACE。
临床应用与阅片要点
- 在3T MRI评估前庭神经鞘瘤、迷路内神经鞘瘤及前庭神经鞘瘤切除术后改变时,pTX-SPACE可改善小结构的边缘显示与检出。
- 采用pTX-SPACE时需注意其信噪比和对比噪声比显著低于标准SPACE。
- 迷路炎评估中pTX-SPACE未显示优于标准SPACE。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To compare image quality and evaluate its clinical importance in common temporal bone pathologies of a pTX-SPACE (parallel transmit [pTX] three-dimensional turbo spin-echo with variable flip angle [SPACE]) magnetic resonance imaging (MRI) sequence improved for spatial resolution to a standard-SPACE sequence exhibiting the same scan time at 3 T.
MATERIALS AND METHODS: Thirty-four patients were examined using a standard-SPACE and resolution improved pTX-SPACE sequence at 3 T MRI. The signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and image quality were assessed. Diseases investigated were vestibular schwannoma (VS), intralabyrinthine schwannoma (ILS), inner ear malformations, labyrinthitis, temporal bone fractures, and situation after VS resection.
RESULTS: Edge definition, intratumoural pattern, discrimination of VS from the modiolus and edge definition of ILS, separability from the spiral lamina, and detectability within cochlear turns were improved on the pTX-SPACE sequence. Detectability of malformations, post-traumatic changes, and discrimination of the cochlear and facial nerve after VS resection was improved on the pTX-SPACE sequence. In labyrinthitis, pTX-SPACE was not superior to standard-SPACE. The SNR and CNR were significantly reduced for pTX-SPACE.
CONCLUSIONS: pTX-SPACE significantly improves the detectability of temporal bone diseases, in particular, VS, ILS, and post-VS resection.
引用
- Schulze M, Reimann K, Seeger A, et al. Improvement in imaging common temporal bone pathologies at 3 T MRI: small structures benefit from a small field of view. Clin Radiol. 2016. PMID: 28034444. doi:10.1016/j.crad.2016.11.019
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。