术中双功能超声测量上颌内动脉颅内外搭桥血流
本研究用术中双功能超声测量上颌内动脉、桡动脉及上颌内动脉-大脑中动脉/大脑后动脉搭桥的血流参数。上颌内动脉与桡动脉内径无显著差异;上颌内动脉-大脑中动脉搭桥所需桡动脉移植物较短、流量较高;术后1个月通畅率分别为95%和100%。术中超声测血流可能有助于决策和预测移植物通畅。
要点
- 上颌内动脉与桡动脉内径无显著差异(2.51±0.34 vs 2.56±0.22 mm,P=.648)。
- 上颌内动脉-大脑中动脉搭桥流量72.6±26.4 mL/min,低于上颌内动脉-大脑后动脉的45.4±6.7 mL/min。
- 术后1个月通畅率:上颌内动脉-大脑中动脉搭桥95%,上颌内动脉-大脑后动脉搭桥100%。
核心结论
- 术中超声测量血流可能有助于神经外科搭桥术中的决策及预测移植物通畅和成功。
研究设计与样本
- 本研究用术中双功能超声测量上颌内动脉(n=20)、桡动脉(n=20)、上颌内动脉-大脑中动脉搭桥(n=42)和上颌内动脉-大脑后动脉搭桥(n=9)的血流动力学参数。
关键影像表现/征象
- 上颌内动脉与桡动脉内径无显著差异(均值±标准差,2.51±0.34 vs 2.56±0.22 mm;P=.648)。
- 上颌内动脉-大脑中动脉搭桥所需桡动脉移植物长度短于上颌内动脉-大脑后动脉搭桥(77.8±2.47 vs 104.8±4.77 mm;P=.001)。
- 上颌内动脉平均流量85.3±18.5 mL/min(95%CI 76.6-93.9),上颌内动脉-大脑中动脉搭桥72.6±26.4 mL/min(95%CI 64.3-80.9),上颌内动脉-大脑后动脉搭桥45.4±6.7 mL/min(95%CI 40.7-50.0)。
- 所有移植物在补救措施成功后均开放,术后1个月早期通畅率上颌内动脉-大脑中动脉搭桥为95%,上颌内动脉-大脑后动脉搭桥为100%。
诊断标准与关键数值
- 上颌内动脉-大脑中动脉搭桥术后1个月早期通畅率为95%,上颌内动脉-大脑后动脉搭桥为100%。
- 桡动脉移植物平均长度88.5±12.78 mm(95%CI 80.8-90.2)。
临床应用与阅片要点
- 术中双功能超声测量血流参数可能有助于搭桥术中决策及预测移植物通畅和成功。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
This study explored the hemodynamic characteristics of a subcranial-intracranial bypass from the internal maxillary artery by measuring blood flow on intraoperative duplex sonography. The hemodynamic parameters of the internal maxillary artery (n = 20), radial artery (n = 20), internal maxillary artery-middle cerebral artery bypass (n = 42), and internal maxillary artery-posterior cerebral artery bypass (n = 9) were measured by intraoperative duplex sonography. There was no significant difference in the internal diameters of the internal maxillary and radial arteries (mean ± SD, 2.51 ± 0.34 versus 2.56 ± 0.22 mm; P = .648). The mean radial artery graft length for subcranial-intracranial bypasses was 88.5 ± 12.78 mm (95% confidence interval [CI], 80.8-90.2 mm). Internal maxillary artery-middle cerebral artery bypasses required a shorter radial artery graft than internal maxillary artery-posterior cerebral artery bypasses (77.8 ± 2.47 versus 104.8 ± 4.77 mm; P = .001). The mean flow volumes were 85.3 ± 18.5 mL/min (95% CI, 76.6-93.9 mL/min) for the internal maxillary artery, 72.6 ± 26.4 mL/min (95% CI, 64.3-80.9 mL/min) for internal maxillary artery-middle cerebral artery bypasses, and 45.4 ± 6.7 mL/min (95% CI, 40.7-50.0 mL/min) for internal maxillary artery-posterior cerebral artery bypasses. All grafts were opened after the success of the salvage procedures had been established, and the early patency rates (1 month after the operation) were 95% for internal maxillary artery-middle cerebral artery bypasses and 100% the internal maxillary artery-posterior cerebral artery bypasses. Measurement of blood flow by intraoperative sonography can be helpful in decision making and predicting graft patency and success after neurosurgical bypass procedures.
引用
- Yu Z, Shi X, Brohi SR, et al. Measurement of Blood Flow in an Intracranial Artery Bypass From the Internal Maxillary Artery by Intraoperative Duplex Sonography. J Ultrasound Med. 2016. PMID: 28026888. doi:10.7863/ultra.16.02011
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。