320排MDCT容积扫描仪全脑CT血管成像动脉-静脉分离的最佳扫描时机
该研究分析60例接受全脑四维CT血管成像的患者,计算颈内动脉与上矢状窦的CT衰减差值(Datt)及动脉与静脉显示视觉评分差值(Dscore),评估团注跟踪触发后动脉-静脉分离的最佳扫描时机。结果显示,颈内动脉对比剂到达时间后6.0秒或8.0秒为动脉期最佳,16.0秒为静脉期最佳,各时间点Datt与Dscore无统计学显著差异。
要点
- 颈内动脉对比剂到达后6.0秒或8.0秒动脉显示最佳,Datt与Dscore均达峰值。
- 静脉最佳显示时机为颈内动脉对比剂到达后16.0秒,此时Datt与Dscore最大。
- 不同扫描时机间Datt(p=0.375)与Dscore(p=0.139)无统计学显著差异。
核心结论
- 全脑CTA动脉-静脉分离的最佳扫描时机为颈内动脉对比剂到达后动脉6.0秒或8.0秒、静脉16.0秒。
研究设计与样本
- 单中心(原文未明确中心数)研究,纳入60例患者行320排MDCT全脑四维CTA,采用团注跟踪技术,以颈内动脉与上矢状窦CT衰减差值及视觉评分差值评估扫描时机。
关键影像表现/征象
- 动脉优势期最大Datt出现在颈内动脉对比剂到达时间后6.0秒和8.0秒,静脉优势期出现在16.0秒和18.0秒。
- 最大Dscore在动脉优势期出现于颈内动脉对比剂到达时间后6.0秒和8.0秒,静脉优势期出现于16.0秒。
诊断标准与关键数值
- Datt为颈内动脉与上矢状窦CT衰减差值;Dscore为颅内动脉平均视觉评分与静脉平均视觉评分之差。
- 动脉优势期Datt与Dscore在6.0秒与8.0秒间无统计学显著差异(Datt p=0.375,Dscore p=0.139)。
临床应用与阅片要点
- 利用320排MDCT团注跟踪技术,可在颈内动脉对比剂到达后6.0秒或8.0秒扫描以优化颅内动脉显示。
- 静脉显影最佳时机为颈内动脉对比剂到达后16.0秒,此时动脉与静脉重叠最少。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: A 320-row multidetector CT (MDCT) is expected for a good artery-vein separation in terms of temporal resolution. However, a shortened scan duration may lead to insufficient vascular enhancement. We assessed the optimal scan timing for the artery-vein separation at whole-brain CT angiography (CTA) when bolus tracking was used at 320-row MDCT.
METHODS: We analyzed 60 patients, who underwent whole-brain four-dimensional CTA. Difference in CT attenuation between the internal carotid artery (ICA) and the superior sagittal sinus (Datt) was calculated in each phase. Using a visual evaluation score for the depiction of arteries and veins, we calculated the difference between the mean score for the intracranial arteries and the mean score for the veins (Dscore). We assessed the time at which the maximum Datt and Dscore were simultaneously observed.
RESULTS: The maximum Datt was observed at 6.0 s and 8.0 s in the arterial-dominant phase and at 16.0 s and 18.0 s in the venous-dominant phase after the contrast media arrival time at the ICA (Taa). The maximum Dscore was observed at 6.0 s and 8.0 s in the arterial-dominant phase and at 16.0 s in the venous-dominant phase after the Taa. There were no statistically significant differences in Datt (p = 0.375) or Dscore (p = 0.139) between these scan timings.
CONCLUSION: The optimal scan timing for artery-vein separation at whole-brain CTA was 6.0 s or 8.0 s for the arteries and 16.0 s for the veins after the Taa. Advances in knowledge: Optimal scan timing allowed us to visualize intracranial arteries or veins with minimal superimposition.
引用
- Shirasaka T, Hiwatashi A, Yamashita K, et al. Optimal scan timing for artery-vein separation at whole-brain CT angiography using a 320-row MDCT volume scanner. Br J Radiol. 2016. PMID: 27995807. doi:10.1259/bjr.20160634
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。