文献速递神经MR

动脉自旋标记脑胶质瘤灌注成像:与MRI引导活检组织病理血管密度的相关性

Perfusion imaging of brain gliomas using arterial spin labeling: correlation with histopathological vascular density in MRI-guided biopsies.
PubMed 文献 · Neuroradiology · 2016-12-06

研究纳入47例初治脑胶质瘤患者,术前行ASL、3D T1增强及T2FLAIR序列,立体定向活检后对CD34染色切片量化微血管密度并与局部脑血流量配准。最终分析41例84个活检点,CBF与MVD呈统计学显著正相关(ρ=0.567,P=.029),提示ASL可用于无创定量评估脑胶质瘤微血管密度。

要点

  • ASL衍生的CBF与胶质瘤活检点MVD呈显著正相关(ρ=0.567,P=.029)。
  • CBF与MVD的相关性基于「点对点」配准,需将CBF区域与立体定向活检位置精确匹配。
  • 6例因脑移位或活检部位配准定位不良被排除,最终分析41例84个活检点。

核心结论

  • ASL可作为无创灌注MR方法用于定量评估脑胶质瘤的微血管密度。

研究设计与样本

  • 研究纳入47例初治脑胶质瘤患者,术前行ASL、3D T1加权钆增强(3D T1C+)及T2液体衰减反转恢复(T2FLAIR)序列,随后行立体定向手术;对CD34染色活检切片组织学量化MVD,并将活检位置与局部CBF测量配准;采用Spearman相关系数分析CBF与MVD的相关性,P≤.05为统计学显著。

诊断标准与关键数值

  • CBF与MVD呈统计学显著正相关(ρ=0.567;P=.029);最终分析41例受试者的84个活检点。

临床应用与阅片要点

  • 作者认为ASL可作为无创灌注MR方法用于定量评估脑胶质瘤的MVD;阅片时需注意CBF与活检点MVD的「点对点」配准,脑移位或配准定位不良可导致活检点被排除。

局限性

  • 47例入组患者中6例因脑移位或术中活检部位配准与定位不良被排除分析。
  • 最终分析仅纳入41例受试者的84个活检点。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

INTRODUCTION: This study was designed to determine if cerebral blood flow (CBF) derived from arterial spin labeling (ASL) perfusion imaging could be used to quantitatively evaluate the microvascular density (MVD) of brain gliomas on a "point-to-point" basis by matching CBF areas and surgical biopsy sites as accurate as possible.

METHODS: The study enrolled 47 patients with treatment-naive brain gliomas who underwent preoperative ASL, 3D T1-weighted imaging with gadolinium contrast enhancement (3D T1C+), and T2 fluid acquisition of inversion recovery (T2FLAIR) sequences before stereotactic surgery. We histologically quantified MVD from CD34-stained sections of stereotactic biopsies and co-registered biopsy locations with localized CBF measurements. The correlation between CBF and MVD was determined using Spearman's correlation coefficient. P ≤ .05 was considered statistically significant.

RESULTS: Of the 47 patients enrolled in the study, 6 were excluded from the analysis because of brain shift or poor co-registration and localization of the biopsy site during surgery. Finally, 84 biopsies from 41 subjects were included in the analysis. CBF showed a statistically significant positive correlation with MVD (ρ = 0.567; P = .029).

CONCLUSION: ASL can be a useful noninvasive perfusion MR method for quantitative evaluation of the MVD of brain gliomas.

来源:Neuroradiology,查看原文。版权归原作者所有。

引用

  1. Ningning D, Haopeng P, Xuefei D, et al. Perfusion imaging of brain gliomas using arterial spin labeling: correlation with histopathological vascular density in MRI-guided biopsies. Neuroradiology. 2016. PMID: 27924360. doi:10.1007/s00234-016-1756-0

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。