磁共振成像在阻塞性泪溢术前评估中的应用:TrueFISP与VIBE序列对比钆增强
研究纳入127例阻塞性泪溢患者,在鼻内镜下泪囊鼻腔吻合术前分别采用无增强1.5-T MR(TrueFISP和VIBE序列,67例)或钆增强1.5-T MR(60例)评估鼻泪管阻塞部位,并以手术所见为参考标准。无增强MRI在所有病例中均能准确识别阻塞部位,而增强MRI将6例(6/60,10.0%)近端狭窄误诊为鼻泪管中段阻塞;无增强MRI准确率显著高于增强MRI(P=0.0256)。
要点
- 无增强1.5-T MR(TrueFISP和VIBE序列)可在术前准确识别鼻泪管阻塞的精确部位。
- 增强MRI将6/60例(10.0%)近端狭窄误诊为鼻泪管中段阻塞,无增强MRI准确率显著更高(P=0.0256)。
- 正确识别阻塞部位后约73%(93/127)患者手术成功,6个月随访无复发。
核心结论
- 在泪溢患者中,无增强MR在鼻泪管狭窄术前特征描述方面高度可靠,甚至比增强MR更有效,且无需进行复杂、耗时且昂贵的局部对比剂给药操作。
研究设计与样本
- 2009年1月至2014年12月诊断并治疗127例阻塞性泪溢患者(35例男性,92例女性;平均年龄60.7±7.48岁,范围42-75岁),均接受内镜下泪囊鼻腔吻合术,为IRB批准方案;67/127例接受无增强1.5-T MR TrueFISP和VIBE序列检查,60/127例接受钆增强1.5-T MR检查;以手术所见作为参考标准验证阻塞真实部位。
关键影像表现/征象
- 无增强MRI在所有病例中均能检测到鼻泪管内阻塞的精确部位。
- 增强MRI将6例(6/60,10.0%)近端狭窄误诊为鼻泪管中段阻塞。
诊断标准与关键数值
- 无增强MRI诊断准确率显著高于增强MRI(P=0.0256)。
- 无增强MRI在所有病例中均能正确识别阻塞部位,增强MRI误诊6/60例(10.0%)近端狭窄为中段阻塞。
- 正确识别阻塞部位后约73%(93/127)患者手术成功,6个月随访无复发。
临床应用与阅片要点
- 无增强1.5-T MR TrueFISP和VIBE序列可用于阻塞性泪溢患者术前鼻泪管阻塞部位的定位。
- 增强MRI可能将近端狭窄误判为鼻泪管中段阻塞,阅片时需注意。
- 无增强MR无需局部对比剂给药,操作更简单、费用更低。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To assess unenhanced magnetic resonance imaging (MRI) in the preoperative evaluation of obstructive epiphora in patients undergoing dacryocystorhinostomy (DCR) and in particular, to evaluate the efficacy of this technique in the detection of the exact level of obstruction occurring in the naso-lachrymal duct (NLD). The correct identification and characterization of the NLD and its obstructions lead to a more effective surgery, preventing recurrent dacryocystitis after the surgical treatment.
METHODS: From January 2009 to December 2014, 127 obstructive epiphoras were diagnosed and treated in 127 patients (35 M, 92 F; mean age 60.7 ± 7.48 years, range 42-75 years) with endoscopic DCR, in a IRB-approved protocol. To precisely define the morphology of the NLD and the site of obstruction, some of these patients (67/127) underwent unenhanced 1.5-T MR with TrueFISP and VIBE sequences, while the remaining (60/127) underwent Gadolinium-enhanced 1.5-T MR. Afterwards, surgery checked the real site of obstruction in both groups of patients (enhanced and unenhanced MR), with surgical outcomes matched with previous MR reports.
RESULTS: In all cases, unenhanced MRI was able to detect the exact site of obstruction along the NLD, allowing a correct planning of surgical endoscopic procedures. On the contrary, enhanced MRI wrongly diagnosed six patients with proximal stenosis (6/60, 10.0%) as intermediate NLD obstruction. Unenhanced MRI was found to be more accurate than enhanced MRI with a statistical significant difference (p value = 0.0256) and obviously cheaper and easier to perform. All imaging reports were verified with surgery. The correct identification of the level of obstruction allowed successful surgery in around 73% (93/127) of patients, who had no recurrence during 6-month follow-up.
CONCLUSION: In patients with epiphora, unenhanced MR showed to be highly reliable and even more effective than enhanced MR in the preoperative characterization of NLD stenosis, with no need of performing complex, time-wasting and expensive procedures for the administration of topical contrast media.
引用
- Somma F, d'Agostino V, Tortora F, et al. Magnetic resonance imaging in the pre-operative evaluation of obstructive epiphora: true-FISP and VIBE vs gadolinium. Radiol Med. 2016. PMID: 27817053. doi:10.1007/s11547-016-0696-4
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。