文献速递骨肌MR

3T磁共振成像对腰椎间盘T1ρ和T2测量值的观察者间及重测可重复性研究

Interobserver and Test-Retest Reproducibility of T1ρ and T2 Measurements of Lumbar Intervertebral Discs by 3T Magnetic Resonance Imaging.
PubMed 文献 · Korean J Radiol · 2016-10-31

研究纳入51名志愿者(女性26名,男性25名,平均年龄54±16.3岁)行3.0T腰椎MRI,其中40名重复测量。两名观察者独立测量L1-2至L5-S1椎间盘髓核的T1ρ和T2值。T1ρ观察者间ICC为0.951,T2为0.672;重测ICC观察者A为T1ρ 0.922、T2 0.617,观察者B为T1ρ 0.914、T2 0.628;T1ρ可重复性显著高于T2(p<0.001)。

要点

  • T1ρ mapping观察者间ICC为0.951,T2 mapping为0.672。
  • T1ρ重测ICC观察者A为0.922、观察者B为0.914;T2分别为0.617、0.628。
  • T1ρ的观察者间及重测可重复性均显著高于T2 mapping(p<0.001)。

核心结论

  • 对于腰椎间盘髓核的定量评估,T1ρ mapping的观察者间和重测可重复性显著高于T2 mapping。

研究设计与样本

  • 研究纳入51名志愿者(女性26名,男性25名,平均年龄54±16.3岁),使用3.0T扫描仪行腰椎MRI,其中40名受试者以相同图像协议重复采集T1ρ和T2测量;两名观察者独立在L1-2至L5-S1椎间盘髓核放置感兴趣区测量;采用双向随机绝对一致性模型计算组内相关系数(ICC),ICC比较采用Z检验,统计学显著性定义为p值<0.05。

诊断标准与关键数值

  • 观察者间可重复性ICC:T1ρ为0.951,T2为0.672;重测可重复性(40名受试者)ICC:观察者A T1ρ为0.922、T2为0.617,观察者B T1ρ为0.914、T2为0.628;T1ρ的观察者间及重测ICC均显著高于T2(p<0.001)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To investigate the interobserver and test-retest reproducibility of T1ρ and T2 measurements of lumbar intervertebral discs using 3T magnetic resonance imaging (MRI).

MATERIALS AND METHODS: This study included a total of 51 volunteers (female, 26; male, 25; mean age, 54 ± 16.3 years) who underwent lumbar spine MRI with a 3.0 T scanner. Amongst these subjects, 40 underwent repeat T1ρ and T2 measurement acquisitions with identical image protocol. Two observers independently performed the region of interest measurements in the nuclei pulposi of the discs from L1-2 through L5-S1 levels. Statistical analysis was performed using intraclass correlation coefficient (ICC) with a two-way random model of absolute agreement. Comparison of the ICC values was done after acquisition of ICC values using Z test. Statistical significance was defined as p value < 0.05.

RESULTS: The ICCs of interobserver reproducibility were 0.951 and 0.672 for T1ρ and T2 mapping, respectively. The ICCs of test-retest reproducibility (40 subjects) for T1ρ and T2 measurements were 0.922 and 0.617 for observer A and 0.914 and 0.628 for observer B, respectively. In the comparison of the aforementioned ICCs, ICCs of interobserver and test-retest reproducibility for T1ρ mapping were significantly higher than T2 mapping (p < 0.001).

CONCLUSION: The interobserver and test-retest reproducibility of T1ρ mapping were significantly higher than those of T2 mapping for the quantitative assessment of nuclei pulposi of lumbar intervertebral discs.