文献速递乳腺乳腺X线

宽扫描角数字乳腺断层摄影与全视野数字乳腺摄影对微钙化检出与表征的诊断性能比较

Diagnostic performance of digital breast tomosynthesis with a wide scan angle compared to full-field digital mammography for the detection and characterization of microcalcifications.
PubMed 文献 · Eur J Radiol · 2016-10-07

该回顾性研究纳入150例全视野数字乳腺摄影(FFDM)和数字乳腺断层摄影(DBT)病例(50例良性、50例恶性经组织学证实的微钙化,50例BI-RADS 1),由4名放射科医生盲法评估微钙化。结果显示DBT与FFDM在微钙化检出率和诊断性能上无显著差异,但读者间差异显著,DBT阅读时间约为FFDM的两倍。

要点

  • 宽扫描角DBT对微钙化的检出与表征与FFDM无显著差异。
  • DBT阅读时间44秒,FFDM为25秒,DBT约为FFDM两倍。
  • 读者间在描述词使用上存在高度变异。

核心结论

  • 宽扫描角DBT能够检出和表征微钙化,与FFDM相比无显著差异;存在读者间变异。

研究设计与样本

  • 回顾性研究,纳入150例FFDM和DBT病例(50例良性、50例恶性组织学证实的微钙化,50例BI-RADS 1),4名放射科医生在独立会话中盲法评估微钙化,参考标准为组织学。

关键影像表现/征象

  • FFDM和DBT对微钙化的检出率和可见性均良好,读者内无差异(P=0.510)。
  • 读者间差异显著(P<0.018)。
  • 仅2个病灶在任何读者使用FFDM或DBT时均未检出。

诊断标准与关键数值

  • DBT诊断性能与FFDM相当,但读者间差异显著(P=0.041)。
  • 使用BI-RADS分类评估可疑程度。
  • 描述词使用存在高度读者间变异。

临床应用与阅片要点

  • 宽扫描角DBT可用于微钙化的检出和表征,与FFDM无显著差异。
  • DBT阅读时间(44秒)约为FFDM(25秒)的两倍。
  • 需注意读者间在微钙化描述和BI-RADS分类上的变异。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To assess the diagnostic performance of digital breast tomosynthesis (DBT), with a wide scan-angle, compared to full-field digital mammography (FFDM), for the detection and characterization of microcalcifications.

METHODS: IRB approval was obtained for this retrospective study. We selected 150 FFDM and DBT (50 benign and 50 malignant histologically verified microcalcifications, 50 cases classified as BI-RADS 1). Four radiologists evaluated, in separate sessions and blinded to patients' history and histology, the presence of microcalcifications. Cases with microcalcifications were assessed for visibility, characteristics, and grade of suspicion using BI-RADS categories. Detection rate and diagnostic performance were calculated. Visibility, lesions' characteristics and reading time were analysed.

RESULTS: Detection rate and visibility were good for both FFDM and DBT, without intra-reader differences (P=0.510). Inter-reader differences were detected (P<0.018). Only two lesions were not detected by any reader on either FFDM or DBT. Diagnostic performance with DBT was as good as that of FFDM, but a significant inter-reader difference was found (P=0.041). High inter-reader variability in the use of the descriptors was found. Reading time for DBT was almost twice that for FFDM (44 and 25s, respectively).

CONCLUSION: Wide scan-angle DBT enabled the detection and characterization of microcalcifications with no significant differences from FFDM. Inter-reader variability was seen.

来源:Eur J Radiol,查看原文。版权归原作者所有。