远程乳腺X线摄影背景下BI-RADS最终评估分类与管理建议的可靠性

Reliability of the BI-RADS Final Assessment Categories and Management Recommendations in a Telemammography Context.
指南 / 共识 · J Am Coll Radiol · 2016-11-01

该回顾性研究采用重复测量析因设计,纳入70例患者、7名放射科医师和4种设备共1960次判读,评估远程乳腺X线摄影中计算机X线摄影、打印胶片、胶片数字化仪和数码相机在BI-RADS词典下判读的一致性。恶性分类的一致性高于BI-RADS最终评估分类,设备间一致性高于设备内一致性,提示所评估设备之间可能具有可互换性。

要点

  • 恶性分类的设备间一致性为几乎完美至相当好(κ 0.70–0.81),高于BI-RADS最终分类(κ 0.52–0.69)。
  • 设备间一致性高于设备内一致性,提示不同设备判读结果可比。
  • 胶片数字化仪与计算机X线摄影之间恶性分类一致性达几乎完美(P < .001)。

核心结论

  • 研究显示设备间一致性很高,尤其是源自恶性分类的管理建议,提示所评估的设备之间可能具有可互换性,从而可为医疗服务不足人群提供低成本医学影像服务。

研究设计与样本

  • 回顾性研究,经作者机构伦理委员会批准,采用重复测量析因设计,共1960次判读(70例患者、7名放射科医师、4种设备),评估远程乳腺X线摄影的计算机X线摄影、打印胶片、胶片数字化仪和数码相机,使用κ系数评价设备内和设备间在恶性分类和BI-RADS最终评估分类上的一致性。

诊断标准与关键数值

  • 恶性分类的设备间一致性:胶片数字化仪与计算机X线摄影之间为几乎完美(P < .001),其他替代方案之间为相当好(P < .001),观察一致率85%–91%,κ值0.70–0.81。
  • BI-RADS最终评估分类的设备间一致性为相当好或中等(P < .001),观察一致率64%–77%,κ值0.52–0.69。
  • 设备间一致性高于设备内一致性。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: The aim of this study was to evaluate the intradevice and interdevice reliability of four alternatives for telemammography-computed radiography, printed film, a film digitizer, and a digital camera-in terms of interpretation agreement when using the BI-RADS® lexicon.

METHODS: The ethics committee of the authors' institution approved this retrospective study. A factorial design with repeated measures with 1,960 interpretations was used (70 patients, seven radiologists, and four devices). Reliability was evaluated using the κ coefficient for intradevice and interdevice agreement on malignancy classification and on BI-RADS final assessment category.

RESULTS: Agreement on malignancy classification was higher than agreement for BI-RADS final assessment category. Interdevice agreement on malignancy classification between the film digitizer and computed radiography was ranked as almost perfect (P < .001), whereas interdevice agreement for the other alternatives was ranked as substantial (P < .001), with observed agreement ranging from 85% to 91% and κ values ranging from 0.70 to 0.81. Interdevice agreement on BI-RADS final assessment category was ranked as substantial or moderate (P < .001), with observed agreement ranging from 64% to 77% and κ values ranging from 0.52 to 0.69. Interdevice agreement was higher than intradevice agreement.

CONCLUSIONS: The results of this study show very high interdevice agreement, especially for management recommendations derived from malignancy classification, which is one of the most important outcomes in screening programs. This study provides evidence to suggest the interchangeability of the devices evaluated, thereby enabling the provision of low-cost medical imaging services to underserved populations.

来源:J Am Coll Radiol,查看原文。版权归原作者所有。

引用

  1. Salazar AJ, Romero JA, Bernal OA, et al. Reliability of the BI-RADS Final Assessment Categories and Management Recommendations in a Telemammography Context. J Am Coll Radiol. 2016. PMID: 27815054. doi:10.1016/j.jacr.2016.08.004

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。