文献速递乳腺US

14G、16G与18G自动切割针活检装置超声引导乳腺肿块活检准确性的比较及文献回顾

Comparison of the accuracy of US-guided biopsy of breast masses performed with 14-gauge, 16-gauge and 18-gauge automated cutting needle biopsy devices, and review of the literature.
PubMed 文献 · Eur Radiol · 2016-11-14

该回顾性研究纳入703例超声引导乳腺空芯针活检,比较14G、16G、18G针的标本不足率、手术不一致率、影像不一致率及DCIS或高危病变升级率。结果显示各针径间诊断准确性无统计学显著差异。作者认为较小针径可自信用于超声引导乳腺空芯针活检。

要点

  • 14G、16G、18G针超声引导乳腺空芯针活检的诊断准确性无统计学显著差异。
  • 标本不足率14G为0%、16G为0.4%、18G为1.9%,组间p=0.084。
  • 手术不一致率14G为2.6%、16G为2.9%、18G为3.8%,组间p=0.76。

核心结论

  • 14G、16G与18G针超声引导乳腺肿块空芯针活检的诊断准确性无统计学显著差异。

研究设计与样本

  • 回顾性研究,纳入703例超声引导乳腺空芯针活检(14G 203例、16G 235例、18G 265例),纳入手术切除或至少2年影像随访的病例。

诊断标准与关键数值

  • 标本不足率14G 0%、16G 0.4%、18G 1.9%(p=0.084);手术不一致率14G 2.6%、16G 2.9%、18G 3.8%(p=0.76);影像不一致率14G 0%、16G 0%、18G 2%(p=1.0);DCIS升级率14G 43%、16G 43%、18G 36%(p=1.00);高危病变升级率14G 38%、16G 25%、18G 55%(p=0.49)。

临床应用与阅片要点

  • 作者认为较小针径可自信用于超声引导乳腺空芯针活检。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To compare the diagnostic accuracy of ultrasound (US)-guided core needle biopsy (CNB) of breast masses performed with 14-gauge, 16-gauge and 18-gauge needles.

METHODS: We retrospectively reviewed the charts of 1,112 patients who underwent US-guided breast CNB with 14-gauge, 16-gauge and 18-gauge needles. Cases with surgical excision or a minimum of 2 years of imaging follow-up were included. Rates of sample inadequacy, discordance with surgical or imaging findings and upgrade of DCIS to invasive cancer or high-risk lesion to in situ or invasive cancer were computed for each needle size.

RESULTS: The study included 703 CNBs: 203 performed with 14-gauge, 235 with 16-gauge and 265 with 18-gauge needles. There were no significant differences between 14-gauge, 16-gauge and 18-gauge needles in rates of specimen inadequacy (0 %, 0.4 % and 1.9 %, respectively) (p = 0.084); surgical discordance (2.6 %, 2.9 % and 3.8 %) (p = 0.76); imaging discordance (0 %, 0 % and 2 %) (p = 1.0); DCIS upgrade (43 %, 43 % and 36 %) (p = 1.00) or high-risk lesion upgrade (38 %, 25 % and 55 %) (p = 0.49).

CONCLUSION: There was no statistically significant difference in diagnostic accuracy of US-guided CNB of breast masses performed with 14-gauge, 16-gauge and 18-gauge needles.

KEY POINTS: • Percutaneous image-guided breast core needle biopsy (CNB) is the standard of care. • Breast CNB with 14-gauge, 16-gauge and 18-gauge needles has similar diagnostic accuracy. • Smaller gauge needles can be confidently used for ultrasound-guided breast CNB.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Huang ML, Hess K, Candelaria RP, et al. Comparison of the accuracy of US-guided biopsy of breast masses performed with 14-gauge, 16-gauge and 18-gauge automated cutting needle biopsy devices, and review of the literature. Eur Radiol. 2016. PMID: 27844099. doi:10.1007/s00330-016-4651-5

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。