文献速递乳腺乳腺X线

为教学与评估创建的模拟筛查乳腺X线摄影模块:放射科住院医师与全国基准的比较

A Simulation Screening Mammography Module Created for Instruction and Assessment: Radiology Residents vs National Benchmarks.
PubMed 文献 · Acad Radiol · 2016-09-13

本研究创建含266例数字筛查乳腺X线摄影(其中7例高危乳腺病变、65例乳腺恶性肿瘤)的模拟模块,39名放射科住院医师在27个月内参与判读;住院医师敏感度为84.5%,与BCSC基准的84.9%相似,特异度为83.2%,低于BCSC基准的90.3%及ACR BI-RADS建议范围88%-95%。

要点

  • 住院医师对乳腺癌的判读敏感度为84.5%,与BCSC基准84.9%相似,在ACR BI-RADS可接受范围≥75%内。
  • 住院医师特异度为83.2%,低于BCSC基准90.3%及ACR BI-RADS建议范围88%-95%。
  • 使用模拟模块判读筛查乳腺X线摄影是训练住院医师检测乳腺癌并达到全国基准的有前景方法。

核心结论

  • 使用模拟模块判读筛查乳腺X线摄影是训练放射科住院医师检测乳腺癌并帮助其达到全国基准能力的有前景方法。

研究设计与样本

  • 前瞻性试点研究,创建含266例数字筛查乳腺X线摄影的模拟模块,其中高危乳腺病变7例、乳腺恶性肿瘤65例;27个月内39名放射科住院医师参与判读,敏感度和特异度与BCSC 2009年前数据全国基准及ACR BI-RADS可接受筛查乳腺X线摄影审计范围比较。

诊断标准与关键数值

  • 住院医师敏感度(初始判读异常即BI-RADS 0的癌症百分比)为84.5%,BCSC基准敏感度(初始检查后1年内组织学诊断癌症的敏感度)为84.9%,ACR BI-RADS医学审计可接受范围为≥75%;住院医师特异度(非癌症病例图像判读阴性即BI-RADS 1或2的百分比)为83.2%,BCSC基准数据报告为90.3%,ACR BI-RADS建议范围为88%-95%。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: To improve mammographic screening training and breast cancer detection, radiology residents participated in a simulation screening mammography module in which they interpreted an enriched set of screening mammograms with known outcomes. This pilot research study evaluates the effectiveness of the simulation module while tracking the progress, efficiency, and accuracy of radiology resident interpretations and also compares their performance against national benchmarks.

MATERIALS AND METHODS: A simulation module was created with 266 digital screening mammograms enriched with high-risk breast lesions (seven cases) and breast malignancies (65 cases). Over a period of 27 months, 39 radiology residents participated in the simulation screening mammography module. Resident sensitivity and specificity were compared to Breast Cancer Surveillance Consortium (BCSC data through 2009) national benchmark and American College of Radiology (ACR) Breast Imaging Reporting and Data System (BI-RADS) acceptable screening mammography audit ranges.

RESULTS: The sensitivity, the percentage of cancers with an abnormal initial interpretation (BI-RADS 0), among residents was 84.5%, similar to the BCSC benchmark sensitivity of 84.9% (sensitivity for tissue diagnosis of cancer within 1 year following the initial examination) and within the acceptable ACR BI-RADS medical audit range of ≥75%. The specificity, the percentage of noncancers that had a negative image interpretation (BI-RADS 1 or 2), among residents was 83.2% compared to 90.3% reported in the BCSC benchmark data, but lower than the suggested ACR BI-RADS range of 88%-95%.

CONCLUSIONS: Using simulation modules for interpretation of screening mammograms is a promising method for training radiology residents to detect breast cancer and to help them achieve competence toward national benchmarks.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Poot JD, Chetlen AL. A Simulation Screening Mammography Module Created for Instruction and Assessment: Radiology Residents vs National Benchmarks. Acad Radiol. 2016. PMID: 27637285. doi:10.1016/j.acra.2016.07.006

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。