文献速递妇产影像腹部CTUS

孕妇创伤:对比增强CT与超声对创伤后胎盘早剥的检测评估

Trauma in pregnant women: assessing detection of post-traumatic placental abruption on contrast-enhanced CT versus ultrasound.
PubMed 文献 · Abdom Radiol (NY) · 2017-01-01

回顾性分析一级创伤中心10年数据,36例孕妇行对比增强CT,其中27例24小时内行超声。完全性胎盘早剥3例、部分性8例。CT阅读者敏感度均为100%,特异度分别为54.5%和56.7%;超声未发现任何早剥异常。CT观察者间一致性低(κ=0.169),超声更低(κ=0.078)。假阳性源于将正常胎盘结构误判为早剥。

要点

  • CT对创伤后胎盘早剥敏感度达100%,但特异度仅54.5%–56.7%。
  • 超声对部分性和完全性胎盘早剥均未显示异常,明显低估诊断。
  • 正常胎盘结构如子叶、年龄相关梗死和边缘窦可误判为早剥。

核心结论

  • 对比增强CT检测创伤后胎盘早剥敏感度高但特异度低,对临床显著早剥的检测优于超声;应避免将正常胎盘结构误判为早剥。

研究设计与样本

  • 回顾性研究,一级创伤中心10年PACS数据库关键词检索孕妇、创伤和/或胎盘早剥;36例行对比增强CT,27例24小时内行超声;两名亚专科培训放射科医师盲法阅片;以分娩时胎盘特征和妊娠结局为参考标准。

关键影像表现/征象

  • 完全性胎盘早剥3例,部分性8例。
  • 部分性和完全性早剥中超声均未见异常表现。
  • CT假阳性来自对正常胎盘结构如子叶、年龄相关梗死和胎盘边缘窦的误判。

诊断标准与关键数值

  • CT阅读者敏感度均为100%(两名阅片者),特异度分别为54.5%和56.7%。
  • CT观察者间一致性κ=0.169,超声κ=0.078。
  • 无不良妊娠/胎儿结局视为无早剥。

临床应用与阅片要点

  • CT对创伤后胎盘早剥敏感度高,但需注意正常胎盘结构可类似早剥而致假阳性。
  • 超声对部分性和完全性胎盘早剥均未显示异常,可明显低估诊断。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To evaluate detection of post-traumatic placental abruption with contrast-enhanced CT (CECT) and comparison with Ultrasound (US).

METHODS: Picture Archive and Date System database at a level-1 trauma center was retrospectively reviewed using keywords pregnancy, trauma, and/or placental abruption over 10 years. CT was compared to US, if performed within 24 h. Two subspecialty-trained radiologists blindly reviewed the studies. Placental features on delivery and pregnancy outcomes were used as reference standard. Lack of adverse pregnancy/fetal outcome was treated as the absence of abruption.

RESULTS: CECT was performed in 36 patients, with 27 US within 24 h. There were three complete and eight partial abruptions. Reader sensitivity for CT was 100% for both reviewers; however, specificity was 54.5% and 56.7%. No sonographic abnormality was noted in both partial and complete abruption. Using kappa statistics, inter-observer agreement was low for both CT (0.169) and US (0.078). False-positive reads were from misinterpretation of normal placental structures like cotyledons, age-related infarcts, and marginal sinus of the placenta.

CONCLUSIONS: CECT identifies post-traumatic placental abruption with high sensitivity but low specificity for clinically significant abruptions, and performs better than US. Pitfalls from normal placental structures mimicking abruption should be avoided. US markedly underdiagnoses abruption.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Jha P, Melendres G, Bijan B, et al. Trauma in pregnant women: assessing detection of post-traumatic placental abruption on contrast-enhanced CT versus ultrasound. Abdom Radiol (NY). 2017. PMID: 27853848. doi:10.1007/s00261-016-0970-x

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。