文献速递妇产影像儿科影像技术与安全US

妊娠期筛查性胎儿解剖超声检查不完整的频率与重要性

Frequency and Importance of Incomplete Screening Fetal Anatomic Sonography in Pregnancy.
PubMed 文献 · J Ultrasound Med · 2016-11-07

这项在高通量学术产科超声中心开展的回顾性队列研究纳入2009年1月至2013年12月孕17至21周单胎妊娠妇女16300例,初始筛查超声中13.2%(2157例)胎儿解剖显示不完整;符合随访条件者中91.5%被建议复查、92.8%实际复查;1560次复查超声中仅0.5%(8例)在原先显示不完整的解剖部分发现异常。

要点

  • 孕17至21周筛查性胎儿解剖超声中约13.2%存在解剖结构显示不完整。
  • 解剖显示不完整但其余正常者中91.5%被建议复查,92.8%实际完成复查。
  • 复查超声仅在0.5%(8/1560)的病例中发现原先未完整显示部位的解剖异常。

核心结论

  • 在该大样本单中心研究中,筛查性胎儿解剖超声显示不完整较为常见,复查建议几乎普遍给出,但复查时发现胎儿解剖异常并不常见。

研究设计与样本

  • 回顾性队列研究,在高通量学术产科超声中心开展;纳入2009年1月至2013年12月孕17至21周单胎妊娠妇女16300例,接受筛查性胎儿解剖超声检查。

诊断标准与关键数值

  • 初始筛查超声解剖显示不完整者2157/16300(13.2%)。
  • 符合随访条件者中91.5%被建议复查,其中92.8%随后接受复查。
  • 1560次复查筛查超声中8次(0.5%)在原先显示不完整的解剖部分发现异常。

局限性

  • 原文结论明确为单中心研究(single-center study)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To determine (1) how often routine screening fetal anatomic sonography fails to completely visualize fetal anatomy; (2) the proportion of women with incomplete ultrasound examinations who are recommended for repeat screening and then undergo repeat sonography; and (3) how often abnormal fetal anatomy is detected on repeat sonography.

METHODS: We conducted a retrospective cohort study at a high-volume academic obstetric ultrasound center. Participants were 16,300 women at 17 through 21 weeks' gestation with a singleton pregnancy presenting for screening anatomic sonography between January 2009 and December 2013. Main outcome measures were (1) incomplete visualization of anatomy at initial screening sonography; (2) among women with incomplete but otherwise normal initial screening ultrasound examinations, recommendation for and performance of repeat sonography; and (3) among women undergoing repeat sonography, discovery of abnormal fetal anatomy within anatomic components that were previously incompletely visualized.

RESULTS: The mean maternal age ± SD was 30.8 ± 6.3 years, and the mean gestational age was 18.8 ± 1.0 weeks. Among 16,300 initial screening ultrasound examinations, 2157 (13.2%) had incomplete visualization of fetal anatomy. Of those women eligible for follow-up, 91.5% were recommended for repeat screening, of whom 92.8% had a subsequent examination. Of 1560 repeat screening ultrasound examinations, 8 (0.5%) showed an abnormality in the components of anatomy that were previously visualized incompletely.

CONCLUSIONS: In this large single-center study, incomplete visualization was common in screening fetal anatomic ultrasound examinations. Recommendations for repeat imaging were nearly universal, but abnormal fetal anatomy was infrequently discovered on repeat screening.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Silvestri MT, Pettker CM, Raney JH, et al. Frequency and Importance of Incomplete Screening Fetal Anatomic Sonography in Pregnancy. J Ultrasound Med. 2016. PMID: 27821652

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。