文献速递泌尿生殖MR

双参数3T磁共振成像用于活检初治人群的前列腺癌检测:对PI-RADS v2的进一步改进?

Biparametric 3T Magnetic Resonance Imaging for prostatic cancer detection in a biopsy-naïve patient population: a further improvement of PI-RADS v2?
PubMed 文献 · Eur J Radiol · 2016-10-14

前瞻性纳入82例未接受过活检、临床怀疑前列腺癌和/或PSA异常的患者,均行多参数MRI(含T2WI、DWI及ADC图、动态增强序列)后行前列腺穿刺活检。两位放射科医生分别基于双参数MRI和多参数MRI方案进行诊断,双参数MRI与多参数MRI总体诊断准确性的AUC分别为0.91和0.93,差异无统计学意义。作者认为双参数MRI方案可行,采集和判读时间更短,诊断准确性相当,且无需注射钆对比剂。

要点

  • 在活检初治人群中,双参数3T MRI(T2WI+DWI/ADC)与多参数MRI的总体诊断准确性AUC分别为0.91和0.93,差异无统计学意义。
  • 双参数MRI方案无需注射钆对比剂,采集和判读时间更短。
  • 共检出34个前列腺肿瘤,其中29个位于外周带、5个位于移行带,Gleason评分范围3+3至5+4。

核心结论

  • 在活检初治患者中,双参数3T MRI前列腺方案与标准多参数MRI方案诊断准确性相当,可缩短采集和判读时间,且无需注射钆对比剂,作者认为该方案可行。

研究设计与样本

  • 前瞻性研究,纳入82例未治疗、未接受过活检、临床怀疑前列腺癌和/或PSA异常的患者(平均年龄65±7.6岁),均行包含T2加权成像、扩散加权成像(含相应表观扩散系数图)和动态增强序列的多参数MRI,随后行前列腺穿刺活检;由两位放射科医生分别基于双参数MRI和多参数MRI方案作出放射学诊断,采用受试者工作特征曲线评估两种方案的诊断效能。

关键影像表现/征象

  • 共检出34个前列腺肿瘤,Gleason评分范围3+3至5+4,其中29个位于外周带、5个位于移行带。
  • 双参数MRI与多参数MRI总体诊断准确性的曲线下面积分别为0.91和0.93,差异无统计学意义(p=n.s.)。

诊断标准与关键数值

  • 双参数MRI总体诊断准确性AUC为0.91,多参数MRI为0.93,两者差异无统计学意义(p=n.s.)。

临床应用与阅片要点

  • 作者认为,与标准多参数MRI方案相比,双参数前列腺MRI方案用于前列腺癌检测是可行的,可缩短采集和判读时间,诊断准确性相当,且无需注射钆对比剂。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To prospectively determine the diagnostic accuracy of a biparametric 3T magnetic resonance imaging protocol (BP-MRI) for prostatic cancer detection, compared to a multiparametric MRI protocol (MP-MRI), in a biopsy naïve patient population.

METHODS: Eighty-two untreated patients (mean age 65±7.6years) with clinical suspicion of prostate cancer and/or altered prostate-specific antigen (PSA) levels underwent a MP-MRI, including T2-weighted imaging, diffusion-weighted imaging (with the correspondent apparent diffusion coefficient maps) and dynamic contrast enhanced sequence, followed by prostate biopsy. Two radiologists reviewed both the BP-MRI and the MP-MRI protocols to establish a radiological diagnosis. Receiver operating characteristics curves were obtained to determine the diagnostic performance of the two protocols.

RESULTS: The mean PSA level was 8.8±8.1ng/ml. A total of 34 prostatic tumors were identified, with a Gleason score that ranged from 3+3 to 5+4. Of these 34 tumors, 29 were located within the peripheral zone and 5 in the transitional zone. BP-MRI and MP-MRI showed a similar performance in terms of overall diagnostic accuracy, with an area under the curve of 0.91 and 0.93, respectively (p=n.s.).

CONCLUSIONS: BP-MRI prostate protocol is feasible for prostatic cancer detection compared to a standard MP-MRI protocol, requiring a shorter acquisition and interpretation time, with comparable diagnostic accuracy to the conventional protocol, without the administration of gadolinium-based contrast agent.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Stanzione A, Imbriaco M, Cocozza S, et al. Biparametric 3T Magnetic Resonance Imaging for prostatic cancer detection in a biopsy-naïve patient population: a further improvement of PI-RADS v2? Eur J Radiol. 2016. PMID: 27842676. doi:10.1016/j.ejrad.2016.10.009

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。