急性与慢性胰腺炎及胰腺肿瘤的声辐射力脉冲剪切波弹性成像(ARFI)
研究纳入195例患者(回顾性95例、前瞻性100例),评估健康胰腺实质、胰腺脂肪瘤病、急性胰腺炎、慢性胰腺炎、腺癌及神经内分泌肿瘤的ARFI剪切波速度。健康实质与脂肪瘤病约1.3m/s,急性胰腺炎、慢性胰腺炎、腺癌依次升高,NET最高3.62m/s;以1.74m/s为恶性病变阈值,敏感度91.1%、特异度60.4%,但各病变间存在明显重叠。
要点
- 健康胰腺实质与胰腺脂肪瘤病的ARFI剪切波速度相近,约1.3m/s。
- 急性胰腺炎、慢性胰腺炎、腺癌的ARFI值依次递增,NET最高达3.62m/s。
- 以1.74m/s为恶性病变阈值,敏感度91.1%、特异度60.4%,各病变间重叠明显。
核心结论
- ARFI剪切波速度在胰腺不同病变中存在差异,急性胰腺炎、慢性胰腺炎及肿瘤性病变均呈高ARFI值,极高弹性值可能提示胰腺恶性病变,但各病变间存在明显重叠。
研究设计与样本
- 前瞻性与回顾性分析,共纳入195例患者,其中回顾性分析95例患者的胰头ARFI弹性成像(特定组另分析胰尾),前瞻性对100例患者行胰头及胰尾ARFI检查。
关键影像表现/征象
- 健康胰腺实质(n=21)与胰腺脂肪瘤病(n=30)的剪切波速度相似,约1.3m/s。
- 急性胰腺炎(n=35)、慢性胰腺炎(n=53)和腺癌(n=52)的ARFI值依次递增。
- 神经内分泌肿瘤(n=4)的剪切波速度最高,达3.62m/s。
- ARFI弹性成像显示急性胰腺炎与慢性胰腺炎或腺癌之间存在相关差异。
诊断标准与关键数值
- 以1.74m/s为诊断恶性疾病的cut-off值,敏感度为91.1%,特异度为60.4%。
临床应用与阅片要点
- ARFI弹性成像可无创评估胰腺组织硬度,急性胰腺炎、慢性胰腺炎及肿瘤性病变均表现为高ARFI值。
- 极高弹性值可能提示胰腺恶性病变,但各病变间存在明显重叠。
局限性
- 原文指出各病变之间存在明显重叠。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
INTRODUCTION: Acoustic Radiation Force Impulse (ARFI) elastography evaluates tissue stiffness non-invasively and has rarely been applied to pancreas examinations so far. In a prospective and retrospective analysis, ARFI shear wave velocities of healthy parenchyma, pancreatic lipomatosis, acute and chronic pancreatitis, adenocarcinoma and neuroendocrine tumor (NET) of the pancreas were evaluated and compared.
MATERIAL AND METHODS: In 95 patients ARFI elastography of the pancreatic head, and also of the tail for a specific group, was analysed retrospectively. Additionally, prospectively in 100 patients ARFI was performed in the head and tail of the pancreas.
RESULTS: A total of 195 patients were included in the study. Healthy parenchyma (n=21) and lipomatosis (n=30) showed similar shear wave velocities of about 1.3m/s. Acute pancreatitis (n=35), chronic pancreatitis (n=53) and adenocarcinoma (n=52) showed consecutively increasing ARFI values, respectively. NET (n=4) revealed the highest shear wave velocities amounting to 3.62m/s. ARFI elastography showed relevant differences between acute pancreatitis and chronic pancreatitis or adenocarcinoma. With a cut-off value of 1.74m/s for the diagnosis of a malignant disease the sensitivity was 91.1% whereas the specificity amounted to 60.4%.
CONCLUSION: ARFI shear wave velocities present differences in various pathologies of the pancreas. Acute and chronic pancreatitis as well as neoplastic lesions show high ARFI values. Very high elasticity values may indicate malignant disease of the pancreas. However, there is a considerable overlap between the entities.
引用
- Goertz RS, Schuderer J, Strobel D, et al. Acoustic radiation force impulse shear wave elastography (ARFI) of acute and chronic pancreatitis and pancreatic tumor. Eur J Radiol. 2016. PMID: 27842669. doi:10.1016/j.ejrad.2016.10.019
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。