促胰液素刺激MRI评估囊性纤维化患者及健康对照的外分泌胰腺功能

Secretin-stimulated MRI assessment of exocrine pancreatic function in patients with cystic fibrosis and healthy controls.
PubMed 文献 · Abdom Radiol (NY) · 2017-01-01

研究纳入19例囊性纤维化(CF)患者与10例健康对照,行促胰液素刺激MRI及胰腺扩散加权成像,并以短程内镜下促胰液素试验为外分泌胰腺功能不全(EPI)参考标准。结果显示CF合并EPI患者胰头刺激前ADC值及分泌肠液量低于健康对照及无EPI的CF患者;刺激后13分钟分泌液量诊断EPI的AUC为0.93(95%CI 0.80-1.00)。作者认为胰腺s-MRI有助于评估外分泌胰腺功能,对CF患者EPI诊断准确性高。

要点

  • 刺激后13分钟分泌液量诊断EPI的AUC为0.93(95%CI 0.80-1.00)。
  • CF合并EPI患者胰头刺激前ADC值低于健康对照及无EPI的CF患者(P<0.001)。
  • CF合并EPI患者分泌肠液量低于健康对照及无EPI的CF患者(P=0.035)。

核心结论

  • 胰腺促胰液素刺激MRI可用于评估外分泌胰腺功能,对CF患者EPI诊断准确性高。

研究设计与样本

  • 研究纳入19例CF患者(中位年龄21岁,范围16-56岁,8名男性)与10例健康对照(中位年龄46岁,范围20-65岁,4名男性),行促胰液素刺激MRI及胰腺DWI,以短程内镜下促胰液素试验为EPI参考标准。

关键影像表现/征象

  • 刺激前及刺激后1、5、9、13分钟采集覆盖十二指肠和小肠的连续冠状位T2加权图像及轴位DWI。
  • CF合并EPI患者胰头刺激前ADC值低于健康对照及无EPI的CF患者(P<0.001)。
  • CF合并EPI患者分泌肠液量低于健康对照及无EPI的CF患者(P=0.035)。

诊断标准与关键数值

  • 刺激后13分钟分泌液量诊断EPI的AUC为0.93(95%CI 0.80-1.00),为ROC分析中诊断准确性最高的指标。

临床应用与阅片要点

  • 采用半自动量化软件评估促胰液素刺激后胰腺分泌液量,以刺激后13分钟分泌液量对EPI诊断准确性最高。
  • 胰头刺激前ADC值及分泌肠液量在CF合并EPI患者中低于健康对照及无EPI的CF患者,阅片时可结合DWI与动态分泌液量综合评估。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Secretin-stimulated magnetic resonance imaging (s-MRI) and pancreatic diffusion weighted imaging (DWI) are novel non-invasive imaging techniques for assessment of exocrine pancreatic insufficiency (EPI). The aim was to validate s-MRI assessed pancreatic secreted volume using novel semi-automatic quantification software, and to assess the ability of s-MRI with DWI to diagnose EPI in patients with cystic fibrosis (CF).

METHODS: s-MRI and DWI was performed in 19 patients with CF (median age 21 years; range 16-56; eight men) and in 10 healthy controls (HC) (median age 46 years; range 20-65; four men). Sequential coronal T2-weighted images covering the duodenum and small bowel and axial DWI were acquired before and 1, 5, 9, and 13 min after secretin stimulation. A short endoscopic secretin test was used as reference method for EPI.

RESULTS: CF patients with EPI had lower apparent diffusion coefficient before secretin in the pancreatic head (P < 0.001) and lower secreted bowel fluid volumes (P = 0.035) compared to HC and CF patients without EPI. ROC curve analyses identified that secreted fluid volume after 13 min yielded the highest diagnostic accuracy for diagnosing EPI (AUC 0.93; 95% CI [0.80-1.00]).

CONCLUSION: Pancreatic s-MRI is useful for the assessment of exocrine pancreatic function with high diagnostic accuracy for the diagnosis of EPI in CF.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。