超声Nakagami成像监测离体猪肝微波消融热损伤的可行性

Feasibility of Using Ultrasonic Nakagami Imaging for Monitoring Microwave-Induced Thermal Lesion in Ex Vivo Porcine Liver.
PubMed 文献 · Ultrasound Med Biol · 2016-11-25

本研究探索超声Nakagami成像评估离体猪肝微波消融所致热损伤的可行性,同步计算消融过程中热损伤区回声振幅和Nakagami参数动态变化及对比噪声比。消融后B模式和Nakagami参数图均出现高回声区,Nakagami参数均值在消融1、3、5分钟后分别升至0.58、0.71和0.91,且Nakagami图像受阴影效应影响较小。初步结果表明Nakagami成像有潜力用于评估微波消融热损伤形成,需进一步在体研究验证。

要点

  • Nakagami参数图在微波消融后显示高回声热损伤区,且受阴影效应影响较B模式小。
  • 消融过程中热损伤区Nakagami参数均值从约0.47升至0.82,消融后降至0.55但仍高于消融前。
  • Nakagami参数图对比噪声比在消融中从0.13升至约0.61,消融后降至0.26。

核心结论

  • 离体猪肝初步研究提示Nakagami成像有潜力用于评估微波消融所致热损伤形成,需进一步在体研究评估其应用潜力。

研究设计与样本

  • 离体猪肝实验研究,探索超声Nakagami成像评估微波消融热损伤的可行性,同步计算热损伤区回声振幅和Nakagami参数动态变化及对比噪声比。

关键影像表现/征象

  • 微波消融后,超声B模式和Nakagami参数图均出现高回声区作为热损伤标志。
  • 热损伤区Nakagami参数均值在消融1、3、5分钟后分别升至0.58、0.71和0.91。
  • 不同消融时长后B模式图像中热损伤区包络振幅无显著差异。
  • 与B模式不同,Nakagami图像在监测消融时受阴影效应影响较小,可见较完整高回声区。

诊断标准与关键数值

  • 热损伤区Nakagami参数均值在消融过程中从约0.47升至0.82,消融后阶段末降至0.55,高于消融前。
  • Nakagami参数图对比噪声比在消融中从0.13升至约0.61,消融后阶段末降至0.26;B模式对应值分别为0.24、0.42和0.17。

临床应用与阅片要点

  • Nakagami成像可能作为微波消融热损伤监测的辅助手段,其图像受阴影效应影响较小。
  • 阅片时注意消融后Nakagami参数图高回声区对应热损伤,参数均值变化可反映损伤形成过程。

局限性

  • 本研究为离体猪肝初步研究,需进一步在体研究评估应用潜力。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

The feasibility of using ultrasonic Nakagami imaging to evaluate thermal lesions induced by microwave ablation (MWA) in ex vivo porcine liver was explored. Dynamic changes in echo amplitudes and Nakagami parameters in the region of the MWA-induced thermal lesion, as well as the contrast-to-noise ratio (CNR) between the MWA-induced thermal lesion and the surrounding normal tissue, were calculated simultaneously during the MWA procedure. After MWA exposure, a bright hyper-echoic region appeared in ultrasonic B-mode and Nakagami parameter images as an indicator of the thermal lesion. Mean values of the Nakagami parameter in the thermal lesion region increased to 0.58, 0.71 and 0.91 after 1, 3 and 5 min of MVA. There were no significant differences in envelope amplitudes in the thermal lesion region among ultrasonic B-mode images obtained after different durations of MWA. Unlike ultrasonic B-mode images, Nakagami images were less affected by the shadow effect in monitoring of MWA exposure, and a fairly complete hyper-echoic region was observed in the Nakagami image. The mean value of the Nakagami parameter increased from approximately 0.47 to 0.82 during MWA exposure. At the end of the postablation stage, the mean value of the Nakagami parameter decreased to 0.55 and was higher than that before MWA exposure. CNR values calculated for Nakagami parameter images increased from 0.13 to approximately 0.61 during MWA and then decreased to 0.26 at the end of the post-ablation stage. The corresponding CNR values calculated for ultrasonic B-mode images were 0.24, 0.42 and 0.17. This preliminary study on ex vivo porcine liver suggested that Nakagami imaging have potential use in evaluating the formation of MWA-induced thermal lesions. Further in vivo studies are needed to evaluate the potential application.