MR弹性成像与振动控制瞬时弹性成像在重度至病态肥胖患者肝纤维化检测中的诊断效能
这项前瞻性研究纳入111例重度至病态肥胖患者,比较MR弹性成像与振动控制瞬时弹性成像(VCTE)检测肝纤维化的诊断效能,以肝活检为参考标准。MR弹性成像检查成功率95.8%,VCTE为81.3%或88.5%;两者检测临床显著肝纤维化(F2-F4期)的AUC分别为0.93和0.91(P=0.551),MR弹性成像技术可靠性更高,观察者间一致性高于肝活检。
要点
- 肥胖患者中MR弹性成像检查成功率95.8%,高于VCTE的81.3%或88.5%。
- 检测F2-F4期肝纤维化,MR弹性成像AUC 0.93,VCTE AUC 0.91,两者差异无统计学意义(P=0.551)。
- MR弹性成像观察者间一致性(ICC 0.95)高于肝活检(ICC 0.89)。
核心结论
- 在肥胖患者群体中,MR弹性成像与VCTE对肝纤维化评估均具有优异的诊断效能;MR弹性成像技术可靠性高于VCTE,观察者间一致性高于肝活检。
研究设计与样本
- 前瞻性、符合HIPAA的研究,经机构审查委员会批准,共纳入111例患者(71例女性、40例男性),均签署书面知情同意。患者接受MR弹性成像(两名阅片者)和VCTE(三名观察者)获取肝硬度测量值以评估肝纤维化,结果与肝活检对照;每份病理标本由两名肝脏病理学家根据METAVIR评分系统或适当时采用Brunt分类进行评估。所有影像观察者均对活检结果设盲,所有肝脏病理学家均对影像结果设盲。评估指标包括检查成功率、观察者间一致性和纤维化检测的诊断准确率。
诊断标准与关键数值
- 肥胖患者群体平均体重指数40.3 kg/m2(95%CI:38.7 kg/m2,41.8 kg/m2)。检查成功率:MR弹性成像95.8%(92/96例),VCTE为81.3%(78/96例)或88.5%(85/96例)。观察者间一致性:MR弹性成像组内相关系数0.95,肝活检0.89。在MR弹性成像和VCTE检查均成功(排除不可靠VCTE检查)的患者中,检测临床显著肝纤维化(F2-F4期)的平均AUC:MR弹性成像0.93(95%CI:0.85,0.97),VCTE 0.91(95%CI:0.83,0.96),P=0.551。
临床应用与阅片要点
- 原文结论指出,在肥胖患者群体中,MR弹性成像与VCTE对肝纤维化评估均具有优异的诊断效能;MR弹性成像技术可靠性高于VCTE,观察者间一致性高于肝活检。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Purpose To evaluate the diagnostic performance and examination success rate of magnetic resonance (MR) elastography and vibration-controlled transient elastography (VCTE) in the detection of hepatic fibrosis in patients with severe to morbid obesity. Materials and Methods This prospective and HIPAA-compliant study was approved by the institutional review board. A total of 111 patients (71 women, 40 men) participated. Written informed consent was obtained from all patients. Patients underwent MR elastography with two readers and VCTE with three observers to acquire liver stiffness measurements for liver fibrosis assessment. The results were compared with those from liver biopsy. Each pathology specimen was evaluated by two hepatopathologists according to the METAVIR scoring system or Brunt classification when appropriate. All imaging observers were blinded to the biopsy results, and all hepatopathologists were blinded to the imaging results. Examination success rate, interobserver agreement, and diagnostic accuracy for fibrosis detection were assessed. Results In this obese patient population (mean body mass index = 40.3 kg/m2; 95% confidence interval [CI]: 38.7 kg/m2, 41.8 kg/m2]), the examination success rate was 95.8% (92 of 96 patients) for MR elastography and 81.3% (78 of 96 patients) or 88.5% (85 of 96 patients) for VCTE. Interobserver agreement was higher with MR elastography than with biopsy (intraclass correlation coefficient, 0.95 vs 0.89). In patients with successful MR elastography and VCTE examinations (excluding unreliable VCTE examinations), both MR elastography and VCTE had excellent diagnostic accuracy in the detection of clinically significant hepatic fibrosis (stage F2-F4) (mean area under the curve: 0.93 [95% CI: 0.85, 0.97] vs 0.91 [95% CI: 0.83, 0.96]; P = .551). Conclusion In this obese patient population, both MR elastography and VCTE had excellent diagnostic performance for assessing hepatic fibrosis; MR elastography was more technically reliable than VCTE and had a higher interobserver agreement than liver biopsy. © RSNA, 2016 Online supplemental material is available for this article. An earlier incorrect version of this article appeared online. This article was corrected on January 25, 2017.
引用
- Chen J, Yin M, Talwalkar JA, et al. Diagnostic Performance of MR Elastography and Vibration-controlled Transient Elastography in the Detection of Hepatic Fibrosis in Patients with Severe to Morbid Obesity. Radiology. 2016. PMID: 27861111. doi:10.1148/radiol.2016160685
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。