文献速递妇产影像介入技术与安全US

高强度聚焦超声无创处理胎盘:一种使用猴模型的初步在体研究

Non-invasive high-intensity focused ultrasound treatment of the placenta: a preliminary in-vivo study using a simian model.
PubMed 文献 · Ultrasound Obstet Gynecol · 2017-10-09

在8只妊娠猴中应用2.5MHz环形高强度聚焦超声(HIFU)经皮无创创建胎盘病灶,共行13次HIFU操作,逐渐增加声功率和暴露时间以确定可重复造模且无并发症的参数。超声见与大体病理相符的高回声区,宏观和显微分析证实胎盘组织坏死;HIFU暴露期间母猴心率、胎猴心率及皮下和羊膜腔内液体温度无显著变化。研究显示HIFU无创作用于妊娠猴胎盘单位可行,短期安全性良好,并可能转化至人类妊娠。

要点

  • HIFU经皮无创可在猴胎盘形成可重复病灶,超声表现为高回声区,与大体病理所见相符。
  • 胎盘HIFU病灶经宏观和显微分析证实为组织坏死。
  • HIFU暴露期间母猴和胎猴参数无显著变化,短期安全性良好。

核心结论

  • 该研究显示HIFU在妊娠猴在体模型中无创作用于胎盘单位可行,短期安全,并可能转化至人类妊娠。

研究设计与样本

  • 初步在体动物研究,8只妊娠猴,使用2.5MHz环形HIFU换能器并整合超声成像探头,共行13次HIFU操作;操作后立即行剖宫产取出胎盘并检查胎猴和母猴腹腔,以超声、大体病理和组织学评估胎盘HIFU病灶。

关键影像表现/征象

  • 胎盘超声检查显示高回声区,与HIFU病灶的大体分析相关性良好。
  • 宏观和显微分析证实暴露于HIFU的胎盘组织坏死。
  • 共观察到5个胎盘病灶,平均直径分别为6.4±0.5mm和7.8±0.7mm,平均深度3.8±1.5mm。

诊断标准与关键数值

  • 通过逐渐增加声功率和暴露时间的总能量递送,确定了一组可在胎盘创建可重复病灶且无并发症的参数。

临床应用与阅片要点

  • 在猴模型中,HIFU经皮放置于皮肤表面即可无创创建胎盘病灶,超声上表现为高回声区。
  • HIFU暴露期间记录母猴心率、胎猴心率及皮下和羊膜腔内液体温度,未见显著变化。

局限性

  • 原文标题与结论均写明为初步研究和在体猴模型研究。
  • 原文结论称该技术仅在短期观察中安全,并称可能转化至人类妊娠。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To demonstrate the feasibility and efficacy of high-intensity focused ultrasound (HIFU) for the non-invasive creation of placental lesions in a simian model.

METHODS: Eight pregnant monkeys were exposed to HIFU treatment after anesthesia, using a toroidal HIFU 2.5-MHz transducer with an integrated ultrasound imaging probe. Lesions on the placental tissue were created non-invasively by placing the HIFU probe on the skin surface. Fetal and maternal parameters, such as maternal heart rate, fetal heart rate and subcutaneous and intra-amniotic fluid temperature, were recorded during HIFU exposure. Cesarean section was performed immediately after the procedure to extract the placenta and examine the fetus and the maternal abdominal cavity. Placental HIFU lesions were assessed by ultrasound, gross pathology and histology.

RESULTS: The mean gestational age of the monkeys was 72 ± 4 days. In total, 13 HIFU procedures were performed. The acoustic power and exposure time were increased progressively. This gradual increase in total energy delivered was used to determine a set of parameters to create reproducible lesions in the placenta without complications. Five placental lesions were observed with average diameters of 6.4 ± 0.5 mm and 7.8 ± 0.7 mm and an average depth of 3.8 ± 1.5 mm. Ultrasound examination of the placentae revealed hyperechoic regions that correlated well with macroscopic analysis of the HIFU lesions. Necrosis of placental tissue exposed to HIFU was confirmed with macroscopic and microscopic analysis. There was no significant variation in maternal and fetal parameters during HIFU exposure.

CONCLUSIONS: This study demonstrates the feasibility of HIFU applied non-invasively to the placental unit in an in-vivo pregnant monkey model. The technique is safe in the immediate short term and is potentially translatable to human pregnancy. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd.

来源:Ultrasound Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. Caloone J, Huissoud C, Kocot A, et al. Non-invasive high-intensity focused ultrasound treatment of the placenta: a preliminary in-vivo study using a simian model. Ultrasound Obstet Gynecol. 2017. PMID: 27804180. doi:10.1002/uog.17350

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。