文献速递胸部心血管外周血管CT

自由呼吸下80 kVp高螺距CT与屏气下100 kVp标准螺距CT检测肺栓塞的前瞻性随机比较

Prospective Randomized Comparison of High-pitch CT at 80 kVp Under Free Breathing with Standard-pitch CT at 100 kVp Under Breath-Hold for Detection of Pulmonary Embolism.
PubMed 文献 · Acad Radiol · 2016-09-14

前瞻性随机比较自由呼吸下高螺距CT(HPCT-FB)与屏气下标准螺距CT(SPCT-BH)检测肺栓塞,100例连续患者随机分组各50例。HPCT组辐射剂量显著更低(2.68 mGy vs 6.01 mGy,P<.001),肺动脉衰减和噪声更高但信噪比相似,诊断信心更高、心脏和呼吸伪影更少、解剖结构可评估性更好、对比剂短暂中断更少。结论认为HPCT-FB可在维持诊断信心、信噪比和解剖结构可评估性的同时显著减少呼吸和运动伪影。

要点

  • HPCT-FB辐射剂量显著低于SPCT-BH(2.68±0.60 mGy vs 6.01±2.26 mGy,P<.001)。
  • HPCT-FB诊断肺栓塞的信心显著更高(P=.048),心脏和呼吸伪影更少(P<.001)。
  • HPCT-FB对比剂短暂中断(Valsalva征象)病例更少(P<.001),信噪比两组相似(P=.258)。

核心结论

  • 与屏气下标准螺距CT相比,自由呼吸下高螺距CT可显著减少呼吸和运动伪影,同时维持诊断信心、血管和支气管结构可评估性及信噪比。

研究设计与样本

  • 前瞻性随机对照研究,连续纳入100例患者(47例女性,平均年龄58.7±16.6岁),随机接受HPCT-FB(n=50)或SPCT-BH(n=50);记录辐射剂量,一名读者测量肺动脉衰减和噪声并计算平均信噪比,两名读者评估图像质量、肺栓塞诊断信心、运动伪影、解剖结构可评估性及对比剂短暂中断(Valsalva动作征象),并计算读者间一致性。

关键影像表现/征象

  • HPCT组肺动脉衰减显著高于SPCT组(479 HU vs 343 HU,P<.001)。
  • HPCT组图像噪声显著高于SPCT组(16 HU vs 10 HU,P<.001),但信噪比两组相似(34 HU vs 38 HU,P=.258)。
  • HPCT组心脏和呼吸伪影显著少于SPCT组(P<.001)。
  • HPCT组对比剂短暂中断(Valsalva动作征象)病例显著少于SPCT组(P<.001)。
  • HPCT组解剖结构可评估性优于SPCT组。

诊断标准与关键数值

  • HPCT组辐射剂量显著低于SPCT组(2.68±0.60 mGy vs 6.01±2.26 mGy,P<.001)。
  • HPCT组肺栓塞诊断信心显著高于SPCT组(P=.048)。

临床应用与阅片要点

  • 自由呼吸下高螺距CT可在不降低信噪比和诊断信心的情况下减少呼吸和运动伪影,并降低辐射剂量。
  • 高螺距CT下肺动脉衰减和图像噪声均增高,但信噪比与标准螺距屏气扫描相似。
  • 高螺距自由呼吸扫描可减少对比剂短暂中断(Valsalva征象)的发生。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: To prospectively compare high-pitch computed tomography (HPCT) under free breathing (FB) with standard-pitch CT (SPCT) under breath-hold (BH) for detection of pulmonary embolism (PE).

MATERIALS AND METHODS: One hundred consecutive patients (47 females; mean age 58.7 ± 16.6) randomly underwent HPCT-FB (n = 50) or SPCT-BH (n = 50). Radiation doses were documented. One reader measured pulmonary artery attenuation and noise; mean signal-to-noise ratio (SNR) was calculated. Two readers assessed image quality, diagnostic confidence for detection of PE, motion artifacts, assessability of anatomical structures, and presence of transient interruption of contrast as sign of Valsalva maneuver. Inter-reader agreement was calculated.

RESULTS: Radiation dose was significantly lower in HPCT compared to SPCT (2.68 ± 0.60 mGy vs 6.01 ± 2.26 mGy; P < .001). Mean pulmonary artery attenuation and image noise were significantly higher in HPCT (attenuation: 479 Hounsfield unit (HU) vs 343HU; P < .001; noise: 16 HU vs 10 HU; P < .001) whereas SNR was similar between groups (34 HU vs 38 HU; P = .258). HPCT had significantly higher diagnostic confidence for PE detection (P = .048), less cardiac and breathing artifacts (P < .001), better assessability of anatomical structures, and fewer cases of transient interruption of contrast (P < .001) compared to the SPCT.

CONCLUSIONS: HPCT-FB allows for a significant reduction of breathing and motion artifacts compared to SPCT-BH. Diagnostic confidence, assessability of vascular and bronchial structures, as well as SNR are maintained.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Martini K, Meier A, Higashigaito K, et al. Prospective Randomized Comparison of High-pitch CT at 80 kVp Under Free Breathing with Standard-pitch CT at 100 kVp Under Breath-Hold for Detection of Pulmonary Embolism. Acad Radiol. 2016. PMID: 27639625. doi:10.1016/j.acra.2016.07.010

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。