双能CT血管成像:双能金属伪影去除算法在腹主动脉腔内修复术后患者中的优缺点
回顾性纳入24例腹主动脉腔内修复术后行双能CT血管成像的患者,评估金属伪影去除后处理与碘基物质图。金属伪影去除客观降低支架近场噪声(60.7 vs 70.1 HU,p=.002)但主观增加近场、远场及血管伪影;无金属伪影去除重建和碘图在6/10例中改善内漏显示,金属伪影去除仅在1/10例因内漏邻近弹簧圈而改善显示。
要点
- 金属伪影去除客观降低支架近场噪声,但主观评分显示近场、远场及血管伪影增加。
- 无金属伪影去除重建和碘图在6/10例中改善内漏显示,金属伪影去除仅在1/10例因内漏邻近弹簧圈而改善显示。
- 作者建议金属伪影去除图像应与60 keV标准重建和碘图联合审阅。
核心结论
- 双能CT金属伪影去除可减少弹簧圈伪影并在1/10例因内漏邻近弹簧圈而改善内漏显示,但在6/10例中损害内漏显示,应结合60 keV标准重建和碘基物质图审阅。
研究设计与样本
- HIPAA合规、IRB批准的回顾性研究,连续纳入24例腹主动脉腔内修复术后患者(年龄76±9岁,7/24(29%)有弹簧圈,9/24(37.5%)有10处内漏),行快速kV切换双能CT血管成像,重建55、60、65、70、75 keV单能图像(有无金属伪影去除)及碘基物质图。
关键影像表现/征象
- 金属伪影去除客观降低支架近场伪影(60.7±25.4 HU vs 70.1±34.2 HU,p=.002)。
- 金属伪影去除主观增加近场(3.2±0.9 vs 2.8±0.6,p<.001)、远场(2.2±0.6 vs 1.6±0.6,p<.001)和血管(3.1±1.1 vs 2.5±0.9,p<.001)伪影评分。
- 弹簧圈近场伪影经金属伪影去除客观降低(72.4±24.8 HU vs 182.7±57.3 HU,p<.001),主观评分降低(4.5±0.5 vs 4.9±0.4,p=.02)。
诊断标准与关键数值
- 主观伪影评分:近场、远场和血管伪影按1=无至5=严重评估。
- 内漏可见性评分:1=最佳至5=不可见。
- 标准重建的对比噪声比在60 keV最佳(38.3±16.8)。
临床应用与阅片要点
- 无金属伪影去除重建和碘基物质图在6/10(60%)例中改善内漏显示(中位数均为1),优于金属伪影去除(中位数3)(p<0.001)。
- 金属伪影去除在1/10(10%)例中因内漏邻近弹簧圈而改善显示。
- 作者建议金属伪影去除图像应与60 keV标准重建和碘基物质图联合审阅。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To evaluate the value of metal artifact reduction (MAR) post-processing and iodine MD images in fast kV-switching dual-energy computed tomography (DECT) in patients after endovascular aortic repair (EVAR).
MATERIALS AND METHODS: Twenty-four consecutive EVAR patients (age 76 ± 9 years, 7/24 (29%) with coils, 9/24 (37.5%) with 10 endoleaks) who underwent DECT angiography were included in this HIPAA-compliant, IRB-approved retrospective study. Monochromatic reconstructions included 55, 60, 65, 70, and 75 keV with and without MAR and iodine MD images. Near field, far field, and vessel artifacts were assessed subjectively (1 = none; 5 = severe) and objectively by measuring noise and contrast-to-noise ratio. Visibility of endoleak was evaluated (1 = optimal; 5 = not visible).
RESULTS: MAR objectively decreased artifacts from EVAR stents in the near field (60.7 ± 25.4 HU vs. 70.1 ± 34.2; p = .002) and subjectively increased near field (3.2 ± 0.9 vs. 2.8 ± 0.6; p < .001), far field (2.2 ± 0.6 vs. 1.6 ± 0.6; p < .001), and vessel (3.1 ± 1.1 vs. 2.5 ± 0.9; p < .001) artifacts. Near-field artifacts from coils were reduced by the MAR objectively (72.4 ± 24.8 vs. 182.7 ± 57.3 HU; p < .001) and subjectively (4.5 ± 0.5 vs. 4.9 ± 0.4; p = .02). CNR of standard reconstructions was optimal at 60 keV (38.3 ± 16.8). Reconstructions without MAR and iodine MD images provided improved endoleak visualization in 6/10 (60%) of cases (median 1 for both) compared to MAR (median 3) (p < 0.001). However, MAR improved visualization in 1/10 (10%) cases due to endoleak location adjacent to a coil.
CONCLUSION: DECT with MAR reduced artifacts from coils and improved endoleak visualization in 1/10 (10%) cases due to location adjacent to a coil. However, MAR impaired endoleak visualization in 6/10 (60%) cases and should be reviewed combined with 60 keV standard reconstructions and iodine MD images.
引用
- Boos J, Fang J, Heidinger BH, et al. Dual energy CT angiography: pros and cons of dual-energy metal artifact reduction algorithm in patients after endovascular aortic repair. Abdom Radiol (NY). 2017. PMID: 27896386. doi:10.1007/s00261-016-0973-7
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。