冠状动脉CT血管成像衍生的血流储备分数与有创血流储备分数评估的比较:伴中度狭窄亚组评价的Meta分析
该Meta分析纳入3项前瞻性多中心试验和2项回顾性单中心研究,共765例患者、1306支血管,比较CT-FFR与单纯cCTA以有创FFR为参考标准的诊断准确性。CT-FFR在保持敏感度无明显变化的同时显著提高特异度,且总体和狭窄30%-70%亚组的AUC均优于单纯cCTA。
要点
- 以有创FFR为参考,CT-FFR诊断血流动力学相关狭窄的汇总敏感度83.7%、特异度74.7%。
- 狭窄30%-70%亚组中,CT-FFR特异度71.7%,明显高于单纯cCTA的35.4%。
- CT-FFR的AUC在总体血管水平为0.90、中度狭窄亚组为0.76,均显著优于单纯cCTA。
核心结论
- 以有创FFR为参考标准检测血流动力学相关狭窄时,CT-FFR显著提高特异度,而敏感度较cCTA无明显变化。
研究设计与样本
- Meta分析纳入3项前瞻性多中心试验和2项回顾性单中心研究,共765例患者、1306支血管,比较有创FFR、cCTA和CT-FFR。
诊断标准与关键数值
- 以有创FFR为参考,CT-FFR汇总敏感度83.7%(95%CI 78.1-89.3)、特异度74.7%(95%CI 52.2-97.1)、阳性预测值64.8%(95%CI 52.1-77.5)、阴性预测值90.1%(95%CI 80.8-99.3)。
- 以有创FFR为参考,单纯cCTA汇总敏感度84.6%(95%CI 78.1-91.1)、特异度49.7%(95%CI 31.1-68.4)、阳性预测值39.0%(95%CI 28.0-50.1)、阴性预测值87.3%(95%CI 72.5-100.0)。
- 634支中度狭窄(30%-70%)血管中,CT-FFR敏感度81.4%(95%CI 70.4-92.9)、特异度71.7%(95%CI 54.5-89.0)、阳性预测值59.4%(95%CI 35.5-83.4)、阴性预测值89.9%(95%CI 85.0-94.7)。
- 634支中度狭窄(30%-70%)血管中,单纯cCTA敏感度90.2%(95%CI 80.6-99.9)、特异度35.4%(95%CI 23.5-47.3)、阳性预测值50.7%(95%CI 30.6-70.8)、阴性预测值82.5%(95%CI 64.5-100.0)。
- CT-FFR的汇总AUC在总体血管水平为0.90(95%CI 0.82-0.98)vs 单纯cCTA 0.74(95%CI 0.63-0.86),P=0.0047;中度狭窄亚组为0.76(95%CI 0.65-0.88)vs 0.57(95%CI 0.49-0.66),P=0.0027。
局限性
- 分析纳入3项前瞻性多中心试验和2项回顾性单中心研究。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: Invasive coronary angiography (ICA) with fractional flow reserve (FFR) assessment is the reference standard for the detection of hemodynamically relevant coronary lesions. We have investigated whether coronary computed tomography angiography (cCTA)-derived FFR (fractional flow reserve from coronary computed tomographic angiography [CT-FFR]) measurement improves diagnostic accuracy over cCTA.
METHODS AND RESULTS: A literature search was performed for studies comparing invasive FFR, cCTA, and CT-FFR. The analysis included three prospective multicenter trials and two retrospective single-center studies; a total of 765 patients and 1306 vessels were included in the meta-analysis. Compared to invasive FFR on a per-lesion basis, CT-FFR reached a pooled sensitivity, specificity, positive predictive value, and negative predictive value of 83.7% (95% confidence interval [CI]: 78.1-89.3), 74.7% (95% CI: 52.2-97.1), 64.8% (95% CI: 52.1-77.5), and 90.1% (95% CI: 80.8-99.3) compared to 84.6% (95% CI: 78.1-91.1), 49.7% (95% CI: 31.1-68.4), 39.0% (95% CI: 28.0-50.1), and 87.3% (95% CI: 72.5-100.0) for cCTA alone. In 634 vessels with intermediate stenosis (30%-70%), sensitivity, specificity, positive predictive value, and negative predictive value were 81.4% (95% CI: 70.4-92.9), 71.7% (95% CI: 54.5-89.0), 59.4% (95% CI: 35.5-83.4), and 89.9% (95% CI: 85.0-94.7) compared to 90.2% (95% CI: 80.6-99.9), 35.4% (95% CI: 23.5-47.3), 50.7% (95% CI: 30.6-70.8), and 82.5% (95% CI: 64.5-100.0) for cCTA alone. The summary area under the receiver operating characteristic curve of CT-FFR was superior to cCTA alone on a per-vessel (0.90 [95% CI: 0.82-0.98] vs 0.74 [95% CI: 0.63-0.86]; P = .0047) and for intermediate stenoses (0.76 [95% CI: 0.65-0.88] vs 0.57 [95% CI: 0.49-0.66]; P = .0027).
CONCLUSION: CT-FFR significantly improves specificity without noticeably altering the sensitivity of cCTA with invasive FFR as a reference standard for the detection of hemodynamically relevant stenosis.
引用
- Baumann S, Renker M, Hetjens S, et al. Comparison of Coronary Computed Tomography Angiography-Derived vs Invasive Fractional Flow Reserve Assessment: Meta-Analysis with Subgroup Evaluation of Intermediate Stenosis. Acad Radiol. 2016. PMID: 27639627. doi:10.1016/j.acra.2016.07.007