双水平试验团注法定制对比剂注射时长在高螺距CT主动脉成像中的应用
本研究回顾性纳入80例接受高螺距70 kVp CT主动脉成像的患者,采用改良双水平试验团注法从时间-衰减曲线得出主动脉根部与股动脉峰值强化间隔,其中40例据此个体化设定注射时长,另40例采用固定时长。个体化注射时长中位15秒(范围11-25秒),较固定时长缩短约50%,对比剂用量由46.2 mL降至23.9 mL(降低50%,P < 0.01),全主动脉平均CT衰减值两组间无显著差异(316-327 HU vs 305-321 HU,P > 0.05)。
要点
- 改良双水平试验团注法可个体化确定高螺距CT主动脉成像的对比剂注射时长。
- 个体化注射时长中位15秒,较固定时长缩短约50%。
- 对比剂用量由46.2 mL降至23.9 mL,降低50%(P < 0.01),图像质量未受不利影响。
核心结论
- 高螺距CT主动脉成像中采用改良双水平试验团注法可显著减少对比剂用量,且不降低图像质量。
研究设计与样本
- 回顾性研究,纳入80例连续接受高螺距70 kVp CT主动脉成像并采用改良双水平试验团注法的受试者,其中40例按时间-衰减曲线结果个体化设定注射时长,其余受试者采用固定注射时长。
诊断标准与关键数值
- 个体化注射时长中位15秒(范围11-25秒),较固定时长缩短约50%;平均对比剂用量由46.2 mL降至23.9 mL(P < 0.01);全主动脉平均CT衰减值个体化组316-327 HU vs 固定时长组305-321 HU(P > 0.05)。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To achieve the efficient usage of contrast material (CM) in high-pitch CT aortography, an appropriate duration of the CM injection is crucial. We used a modification of the double-level test bolus method for determination of proper injection duration with the aim of evaluating the image quality of tailored-duration CM injection compared with that of a fixed duration.
MATERIALS AND METHODS: The institutional review board approved retrospective review of 80 consecutive subjects who had undergone high-pitch 70-kVp CT aortography with a modified double-level test bolus method. The interval between peak enhancement at the aortic root and femoral artery was derived from the time/attenuation curves. A total of 40 subjects underwent CT aortography with individually set duration time from the results. The remaining subjects underwent CT aortography with a fixed-duration time. The density values at several parts of the aorta were assessed. The differences in image quality and CM amount used for each method were assessed by Welch test.
RESULTS: The injection duration was almost 50% shorter (median, 15 seconds; range, 11-25 seconds) when individually tailored. The mean CM amount was reduced by 50% (46.2-23.9 mL, P < 0.01). The range of mean CT attenuation throughout the aorta was not significantly different between the 2 methods (316-327 HU and 305-321 HU, P > 0.05, respectively).
CONCLUSIONS: The modified double-level test bolus method in high-pitch CT aortography can significantly reduce the amount of CM without adversely affecting image quality.