对比增强磁共振血管成像主动脉体积测量:作为监测二叶式主动脉瓣主动脉病变敏感方法的可行性

Aortic Volumetry at Contrast-Enhanced Magnetic Resonance Angiography: Feasibility as a Sensitive Method for Monitoring Bicuspid Aortic Valve Aortopathy.
PubMed 文献 · Invest Radiol · 2017-01-01

回顾性研究纳入20例二叶式主动脉瓣患者,比较对比增强磁共振血管成像体积测量与二维直径测量识别胸主动脉瘤生长的可靠性;体积测量的观察者内变异系数更低、组内相关系数更高,体积年增长6±3 mL/y(4%±3%),提示体积测量可能更敏感且受误差影响更小。

要点

  • 体积测量的观察者内变异系数为0.02,低于SOV的0.01与MAA的0.02(原文如此)。
  • 体积测量的组内相关系数为0.95,高于SOV的0.83与MAA的0.86。
  • 体积测量年增长6±3 mL/y(4%±3%),直径测量年增长0.2–0.7 mm/y。

核心结论

  • 三维对比增强磁共振血管成像体积测量在百分比增长方面效应更大、组内相关系数更好、变异系数略低。
  • 体积测量可能对生长更敏感,且可能比直径测量更少受误差影响。

研究设计与样本

  • 回顾性、机构审查委员会批准且符合健康保险流通与责任法案的研究,纳入20例二叶式主动脉瓣患者(45±8.9岁,20%为女性)。
  • 患者接受系列对比增强磁共振血管成像,最短影像随访11个月,平均随访2.6±0.82年。
  • 磁共振成像在1.5 T进行,采用心电图门控、时间分辨对比增强磁共振血管成像。
  • 独立观察者测量Valsalva窦(SOV)和升主动脉中段(MAA)直径,以及主动脉瓣环至无名动脉分支之间的升主动脉体积。

关键影像表现/征象

  • 基线至随访平均测量值:SOV为42±3 mm至42±3 mm(P=0.11),MAA为46±4 mm至47±4 mm(P<0.05),体积为130±23 mL至144±24 mL(P<0.05)。
  • 平均大小变化:SOV为0.2±0.6 mm/y(1%±2%),MAA为0.5±0.8 mm/y(1%±2%),最大生长直径(DMG)为0.7±0.7 mm/y(2%±2%),体积测量为6±3 mL/y(4%±3%)。

诊断标准与关键数值

  • 观察者内变异系数:SOV为0.01、MAA为0.02、体积为0.02;观察者间变异系数:SOV为0.02、MAA为0.03、体积为0.04。
  • 组内相关系数:SOV为0.83、MAA为0.86、DMG为0.90、体积为0.95。
  • 最大生长直径(DMG)定义为SOV或MAA中生长速率较快的直径。

临床应用与阅片要点

  • 体积测量在百分比增长方面显示出更大效应,且组内相关系数更高、变异系数略低,可能对生长更敏感并可能更少受误差影响。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Bicuspid aortic valve patients can develop thoracic aortic aneurysms and therefore require serial imaging to monitor aortic growth. This study investigates the reliability of contrast-enhanced magnetic resonance angiography (CEMRA) volumetry compared with 2-dimensional diameter measurements to identify thoracic aortic aneurysm growth.

MATERIALS AND METHODS: A retrospective, institutional review board-approved, and Health Insurance Portability and Accountability Act-compliant study was conducted on 20 bicuspid aortic valve patients (45 ± 8.9 years, 20% women) who underwent serial CEMRA with a minimum imaging follow-up of 11 months. Magnetic resonance imaging was performed at 1.5 T with electrocardiogram-gated, time-resolved CEMRA. Independent observers measured the diameter at the sinuses of Valsalva (SOVs) and mid ascending aorta (MAA) as well as ascending aorta volume between the aortic valve annulus and innominate branch. Intraobserver/interobserver coefficient of variation (COV) and intraclass correlation coefficient (ICC) were computed to assess reliability. Growth rates were calculated and assessed by Student t test (P < 0.05, significant). The diameter of maximal growth (DMG), defined as the diameter at SOV or MAA with the faster growth rate, was recorded.

RESULTS: The mean time of follow-up was 2.6 ± 0.82 years. The intraobserver COV was 0.01 for SOV, 0.02 for MAA, and 0.02 for volume (interobserver COV: 0.02, 0.03, 0.04, respectively). The ICC was 0.83 for SOV, 0.86 for MAA, 0.90 for DMG, and 0.95 for volume. Average aortic measurements at baseline and (follow-up) were 42 ± 3 mm (42 ± 3 mm, P = 0.11) at SOV, 46 ± 4 mm (47 ± 4 mm, P < 0.05) at MAA, and 130 ± 23 mL (144 ± 24 mL, P < 0.05). Average size changes were 0.2 ± 0.6 mm/y (1% ± 2%) at SOV, 0.5 ± 0.8 mm/y (1% ± 2%) at MAA, 0.7 ± 0.7 mm/y (2% ± 2%) at DMG, and 6 ± 3 mL/y (4% ± 3%) with volumetry.

CONCLUSIONS: Three-dimensional CEMRA volumetry exhibited a larger effect when examining percentage growth, a better ICC, and a marginally lower COV. Volumetry may be more sensitive to growth and possibly less affected by error than diameter measurements.