文献速递胸部CT

迭代重建对计算机断层扫描肺气肿客观与主观评估的影响:一项前瞻性研究

Impact of iterative reconstructions on objective and subjective emphysema assessment with computed tomography: a prospective study.
PubMed 文献 · Eur Radiol · 2016-11-15

该前瞻性研究纳入110例平扫胸部CT,比较不同水平迭代重建(IR)与滤波反投影(FBP)对肺气肿评估的影响。结果显示肺容积在各IR水平下稳定(P≥0.057),但肺气肿指数(EI)随IR水平显著下降(P<0.001),最高IR水平导致EI下降33-36%;主观评估不受IR影响,阅片者间一致性良好(W≥0.86)。

要点

  • 肺气肿客观定量(EI)对迭代重建敏感,最高IR水平使EI下降33-36%。
  • 主观视觉评估肺气肿不受迭代重建影响,阅片者间一致性良好。
  • 肺容积在各IR水平下保持稳定,但最小肺密度在不同算法间有显著差异。

核心结论

  • 本研究中两种商用IR算法在相同辐射剂量下与标准FBP重建相比显著改变EI,但未改变视觉评估。

研究设计与样本

  • 前瞻性研究,纳入110例平扫胸部CT,使用两台不同扫描仪,单次采集后以不同IR水平及FBP重建,比较EI、肺容积和体素密度。

关键影像表现/征象

  • 肺容积在两台设备所有IR水平下稳定(P≥0.057)。
  • EI在两台设备上使用任何IR水平均显著下降(P<0.001)。
  • 最高IR水平导致EI下降33-36%。
  • 不同算法间最小肺密度有显著差异(P<0.003)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To prospectively evaluate the impact of iterative reconstruction (IR) algorithms on pulmonary emphysema assessment as compared to filtered back projection (FBP).

METHODS: One hundred ten unenhanced chest CT examinations were obtained on two different scanners. Image reconstructions from a single acquisition were done with different levels of IR and compared with FBP on the basis of the emphysema index (EI), lung volume and voxel densities. Objective emphysema assessment was performed with 3D software provided by each manufacturer. Subjective assessment of emphysema was performed as a blinded evaluation. Quantitative and subjective values were compared using repeated ANOVA analysis, Bland-Altman analysis and Kendall's coefficient of concordance (W).

RESULTS: Lung volumes are stable on both units, throughout all IR levels (P ≥ 0.057). EI significantly decreases on both units with the use of any level of IR (P < 0.001). The highest levels of IR are responsible for a decrease of 33-36 % of EI. Significant differences in minimal lung density are found between the different algorithms (P < 0.003). Intra- and inter-reader concordance for emphysema characterisation is generally good (W ≥ 0.77 and W ≥ 0.86, respectively).

CONCLUSIONS: Both commercially available IR algorithms used in this study significantly changed EI but did not alter visual assessment compared to standard FBP reconstruction at identical radiation exposure.

KEY POINTS: • Objective quantification of pulmonary emphysema is sensitive to iterative reconstructions • Subjective evaluation of pulmonary emphysema is not influenced by iterative reconstructions • Consistency in reconstruction algorithms is of paramount importance for pulmonary emphysema monitoring.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Martin SP, Gariani J, Hachulla AL, et al. Impact of iterative reconstructions on objective and subjective emphysema assessment with computed tomography: a prospective study. Eur Radiol. 2016. PMID: 27847999. doi:10.1007/s00330-016-4641-7

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。