慢性阻塞性肺疾病患者双能CT评估区域性肺气肿、气体潴留与氙气通气
研究前瞻性纳入52例COPD患者,行氙气通气双能CT的洗入与洗出期扫描及肺功能检查,比较吸气/呼气CT的肺实质衰减变化与氙气动态通气变化。结果显示肺气肿指数、气体潴留指数和气体潴留指数与氙气通气参数显著相关,且氙气通气动态在肺气肿、过度充气和正常肺区之间存在差异。
要点
- 肺气肿指数、气体潴留指数和气体潴留指数与氙气洗入、洗出及动态参数均显著相关(p<0.01)。
- 氙气动态参数在肺气肿区、过度充气区和正常肺区之间差异显著(p<0.01)。
- 除用力肺活量外,所有CT参数与肺功能检查指标均显著相关。
核心结论
- 吸气/呼气CT的肺实质衰减变化与氙气洗入/洗出CT的氙气动态变化显著相关,且肺气肿区域间氙气通气动态存在改变。
研究设计与样本
- 前瞻性纳入52例COPD患者,行氙气通气双能CT洗入期和洗出期扫描及肺功能检查,在虚拟平扫图像和通气图像上计算全肺及肺气肿区、过度充气区、正常区三个区域的衰减参数和氙气通气参数。
诊断标准与关键数值
- 肺气肿指数与氙气洗入、洗出、动态参数的相关系数分别为R=-0.744、-0.562、-0.737(p<0.01)。
- 气体潴留指数与氙气洗入、洗出、动态参数的相关系数分别为R=-0.621、-0.442、-0.629(p<0.01)。
- 气体潴留指数与氙气洗入、洗出、动态参数的相关系数分别为R=-0.600、-0.421、-0.610(p<0.01)。
临床应用与阅片要点
- 除用力肺活量外,所有CT参数与肺功能检查指标均显著相关,提示衰减参数和氙气参数可联合用于评估肺功能。
- 氙气动态参数在肺气肿区、过度充气区和正常肺区之间差异显著,阅片时可关注不同肺区的通气动态变化。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To compare the parenchymal attenuation change between inspiration/expiration CTs with dynamic ventilation change between xenon wash-in (WI) inspiration and wash-out (WO) expiration CTs.
METHODS: 52 prospectively enrolled COPD patients underwent xenon ventilation dual-energy CT during WI and WO periods and pulmonary function tests (PFTs). The parenchymal attenuation parameters (emphysema index (EI), gas-trapping index (GTI) and air-trapping index (ATI)) and xenon ventilation parameters (xenon in WI (Xe-WI), xenon in WO (Xe-WO) and xenon dynamic (Xe-Dyna)) of whole lung and three divided areas (emphysema, hyperinflation and normal) were calculated on virtual non-contrast images and ventilation images. Pearson correlation, linear regression analysis and one-way ANOVA were performed.
RESULTS: EI, GTI and ATI showed a significant correlation with Xe-WI, Xe-WO and Xe-Dyna (EI R = -.744, -.562, -.737; GTI R = -.621, -.442, -.629; ATI R = -.600, -.421, -.610, respectively, p < 0.01). All CT parameters showed significant correlation with PFTs except forced vital capacity (FVC). There was a significant difference in GTI, ATI and Xe-Dyna in each lung area (p < 0.01).
CONCLUSIONS: The parenchymal attenuation change between inspiration/expiration CTs and xenon dynamic change between xenon WI- and WO-CTs correlate significantly. There are alterations in the dynamics of xenon ventilation between areas of emphysema.
KEY POINTS: • The xenon ventilation change correlates with the parenchymal attenuation change. • The xenon ventilation change shows the difference between three lung areas. • The combination of attenuation and xenon can predict more accurate PFTs.
引用
- Lee SM, Seo JB, Hwang HJ, et al. Assessment of regional emphysema, air-trapping and Xenon-ventilation using dual-energy computed tomography in chronic obstructive pulmonary disease patients. Eur Radiol. 2016. PMID: 27882425. doi:10.1007/s00330-016-4657-z
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。