全身麻醉下屏气PET/CT引导肿瘤消融:肿瘤图像配准准确性与预测消融区重叠度

Breath-hold PET/CT-guided tumour ablation under general anaesthesia: accuracy of tumour image registration and projected ablation zone overlap.
PubMed 文献 · Clin Radiol · 2016-11-23

研究纳入8例患者共12次全身麻醉下屏气PET/CT引导经皮肿瘤消融术、治疗肺部、肝脏或肾上腺20个肿瘤,由4名读者在PET与CT采集上标记肿瘤中心评估二维和三维空间配准误差,并用Dice相似系数比较PET与CT预测消融体积重叠度;平均三维配准误差4.4 mm,平均DSC 0.72,技术成功率100%,19个肿瘤中1个(5.3%)进展,结果提示仅PET可见肿瘤可被准确定位并消融。

要点

  • 屏气PET/CT的肿瘤三维配准平均误差为4.4 mm(范围0.36–10.74)。
  • PET与CT预测消融体积的平均DSC为0.72(±0.19)。
  • 技术成功率100%,19个肿瘤中1个(5.3%)局部进展。

核心结论

  • 单次屏气PET/CT的PET与CT采集之间可实现准确的肿瘤空间配准和预测消融体积的实质性重叠,结果提示仅PET可见的肿瘤可被准确定位并消融。

研究设计与样本

  • 单中心前瞻性研究?原文未写明研究类型;8例患者接受12次全身麻醉下屏气PET/CT引导经皮肿瘤消融术,治疗肺部、肝脏或肾上腺20个肿瘤;4名读者在PET和CT采集上标记肿瘤中心,评估二维和三维空间配准误差,用Dice相似系数比较PET与CT预测消融体积重叠,采用重复测量方差分析评估观察者间差异。

诊断标准与关键数值

  • 肿瘤二维PET/CT配准误差均值在x、y、z平面分别为1.02 mm(范围0.01–5.02)、1.89 mm(范围0.03–7.85)、3.05 mm(范围0–10);平均三维配准误差4.4 mm(范围0.36–10.74);PET与CT预测消融体积的平均DSC为0.72(±0.19);三维配准误差(p=0.73)和DSC(p=0.54)均无显著观察者间差异;技术成功率100%;19个肿瘤中1个(5.3%)进展。

临床应用与阅片要点

  • 原文结论提示,仅PET可见的肿瘤可借助单次屏气PET/CT被准确定位并消融。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To assess single-breath-hold combined positron-emission tomography/computed tomography (PET/CT) for accuracy of tumour image registration and projected ablation volume overlap in patients undergoing percutaneous PET/CT-guided tumour-ablation procedures under general anaesthesia.

MATERIALS AND METHODS: Eight patients underwent 12 PET/CT-guided tumour-ablation procedures to treat 20 tumours in the lung, liver, or adrenal gland. Using breath-hold PET/CT, the centre of the tumour was marked on each PET and CT acquisition by four readers to assess two- (2D) and three-dimensional (3D) spatial misregistration. Overlap of PET and CT projected ablation volumes were compared using the Dice similarity coefficient (DSC). Interobserver differences were assessed with repeated measure analysis of variance (ANOVA). Technical success and local progression rates were noted.

RESULTS: Mean tumour 2D PET/CT misregistrations were 1.02 mm (range 0.01-5.02), 1.89 (0.03-7.85), and 3.05 (0-10) in the x, y, and z planes. Mean 3D misregistration was 4.4 mm (0.36-10.74). Mean projected PET/CT ablation volume DSC was 0.72 (±0.19). No significant interobserver differences in 3D misregistration (p=0.73) or DSC (p=0.54) were observed. Technical success of ablations was 100%; one (5.3%) of 19 tumours progressed.

CONCLUSION: Accurate spatial registration of tumours and substantial overlap of projected ablation volumes are achievable when comparing PET and CT acquisitions from single-breath-hold PET/CT. The results suggest that tumours visible only at PET could be accurately targeted and ablated using this technique.

来源:Clin Radiol,查看原文。版权归原作者所有。