儿童胸部CT的辐射剂量水平:499例双源单能CT检查经验
该研究回顾性记录499例体重<50 kg儿童双源单能胸部CT的剂量长度乘积,按体重分五组,均采用高时间分辨率(75 ms)、高螺距模式和体重适配毫安选择。研究建立了各体重组的辐射剂量水平,五组间DLP32、CTDIvol32和SSDE差异有统计学意义(P < 0.0001)。
要点
- 儿童胸部CT采用80 kVp、40–90 mAs、螺距2.0或3.0,体重分组中位DLP32为15–37 mGy.cm。
- 体重分组中位CTDIvol32为0.78–1.25 mGy,中位SSDE为1.6–2.1 mGy。
- 五组体重间DLP32、CTDIvol32和SSDE差异有统计学意义(P < 0.0001)。
核心结论
- 本研究建立了单中心双源单kVp儿童胸部CT的辐射剂量水平,五个体重组中位DLP32为15–37 mGy.cm、CTDIvol32为0.78–1.25 mGy、SSDE为1.6–2.1 mGy。
研究设计与样本
- 回顾性记录499例连续儿童(<50 kg)双源单能胸部CT检查的剂量长度乘积,按体重分五组:组1(<10 kg,n=129)、组2(10–20 kg,n=176)、组3(20–30 kg,n=99)、组4(30–40 kg,n=58)、组5(40–49 kg,n=37);均采用高时间分辨率(75 ms)、高螺距模式和体重适配毫安选择。
诊断标准与关键数值
- 全部检查采用80 kVp,毫安范围40–90 mAs,螺距2.0(n=162;32.5%)或3.0(n=337;67.5%);平均数据采集时间522.8 ± 192.0 ms(四分位距390–610;中位数490);总人群平均CTDIvol32为0.83 mGy(标准差0.20 mGy;四分位距0.72–0.94;中位数0.78),平均DLP32为21.4 mGy.cm(标准差9.1 mGy.cm;四分位距15–25;中位数19.0),平均SSDE为1.7 mGy(标准差0.4 mGy;四分位距1.5–1.9;中位数1.7);五体重组间DLP32、CTDIvol32和SSDE差异有统计学意义(P < 0.0001)。
临床应用与阅片要点
- 本研究给出各体重组儿童双源单能胸部CT的剂量参考水平,可用于日常剂量监测与报告中的剂量记录对照。
局限性
- 本研究为单中心经验。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: The availability of dual-source technology has introduced the possibility of scanning children at lower kVp with a high-pitch mode, combining high-speed data acquisition and high temporal resolution.
OBJECTIVE: To establish the radiation dose levels of dual-source, single-energy chest CT examinations in children.
MATERIALS AND METHODS: We retrospectively recorded the dose-length product (DLP) of 499 consecutive examinations obtained in children <50 kg, divided into five weight groups: group 1 (<10 kg, n = 129); group 2 (10-20 kg, n = 176); group 3 (20-30 kg, n = 99), group 4 (30-40 kg, n = 58) and group 5 (40-49 kg, n = 37). All CT examinations were performed with high temporal resolution (75 ms), a high-pitch mode and a weight-adapted selection of the milliamperage.
RESULTS: CT examinations were obtained at 80 kVp with a milliamperage ranging between 40 mAs and 90 mAs, and a pitch of 2.0 (n = 162; 32.5%) or 3.0 (n = 337; 67.5%). The mean duration of data acquisition was 522.8 ± 192.0 ms (interquartile range 390 to 610; median 490). In the study population, the mean CT dose index volume (CTDIvol32) was 0.83 mGy (standard deviation [SD] 0.20 mGy; interquartile range 0.72 to 0.94; median 0.78); the mean DLP32 was 21.4 mGy.cm (SD 9.1 mGy.cm; interquartile range 15 to 25; median 19.0); and the mean size-specific dose estimate (SSDE) was 1.7 mGy (SD 0.4 mGy; interquartile range 1.5 to 1.9; median 1.7). The DLP32, CTDIvol32 and SSDE were found to be statistically significant in the five weight categories (P < 0.0001).
CONCLUSION: This study establishes the radiation dose levels for dual-source, single-kVp chest CT from a single center. In the five weight categories, the median values varied 15-37 mGy.cm for the DLP32, 0.78-1.25 mGy for the CTDIvol32 and 1.6-2.1 mGy for the SSDE.
引用
- Martine RJ, Santangelo T, Colas L, et al. Radiation dose levels in pediatric chest CT: experience in 499 children evaluated with dual-source single-energy CT. Pediatr Radiol. 2016. PMID: 27830296. doi:10.1007/s00247-016-3731-7
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。