文献速递胸部CTPET

FDG-PET/CT预测非特异性间质性肺炎肺功能改善的初步研究

FDG-PET/CT in the prediction of pulmonary function improvement in nonspecific interstitial pneumonia. A Pilot Study.
PubMed 文献 · Eur J Radiol · 2016-10-04

纳入18例非特异性间质性肺炎患者,用FDG-PET/CT记录SUVmax、FDG摄取范围及HRCT表现。所有患者肺FDG摄取增高,摄取范围与治疗后肺功能改善相关(p=0.03),ROC曲线下面积0.85±0.11,阈值21%时敏感度/特异度88%/80%。

要点

  • 所有NSIP患者均见肺FDG摄取增高,中位SUVmax 3.1,中位摄取范围19%。
  • FDG摄取范围与治疗后FVC改善>10%相关(p=0.03),SUVmax与HRCT纤维化评分无此关联(p>0.5)。
  • 摄取范围阈值21%时,预测肺功能改善的敏感度88%、特异度80%,AUC 0.85±0.11。

核心结论

  • 所有NSIP患者均见FDG摄取增高,炎症性与纤维化HRCT病灶均可摄取;FDG摄取范围的量化可能有助于预测治疗下的功能改善。

研究设计与样本

  • 初步研究,纳入18例NSIP患者,采用FDG-PET/CT记录SUVmax、FDG摄取范围(占肺容积百分比)、HRCT基本病灶及HRCT纤维化评分;用逻辑回归和ROC曲线分析参数对肺功能改善的预测价值(n=13/18)。

诊断标准与关键数值

  • 肺功能改善定义为治疗后用力肺活量增加>10%;FDG摄取范围预测肺功能改善的AUC为0.85±0.11,阈值21%时敏感度88%、特异度80%;SUVmax与HRCT纤维化评分对肺功能改善无预测价值(p>0.5)。

临床应用与阅片要点

  • 作者认为FDG摄取范围的量化可能有助于预测NSIP患者治疗下的功能改善。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Our study aimed to analyse the characteristics of nonspecific interstitial pneumonia (NSIP) using FDG-PET/CT (PET) and to evaluate its ability to predict the therapeutic response.

PROCEDURES: Eighteen NSIP patients were included. Maximum standardized uptake value (SUVmax), FDG uptake extent (in percentage of lung volume), high resolution CT scan (HRCT) elementary lesions, and HRCT fibrosis score were recorded. The predictive value of the parameters for lung function improvement was evaluated using logistic regression and Receiver Operating Characteristic (ROC) curve analysis (n=13/18).

RESULTS: All patients had an increased pulmonary FDG uptake (median SUVmax=3.1 [2-7.6]), with a median extent of 19% [6-67]. Consolidations, ground-glass opacities, honeycombing and reticulations showed uptake in 90%, 89%, 85% and 76%, respectively. FDG uptake extent was associated with improvement of pulmonary function under treatment (increase in forced vital capacity>10%, p=0.03), whereas SUVmax and HRCT fibrosis score were not (p>0.5). For FDG uptake extent, ROC analysis showed an area under the curve at 0.85±0.11 and sensitivity/specificity was 88%/80% for a threshold fixed at 21%.

CONCLUSIONS: Increased FDG uptake was observed in all NSIP patients, both in inflammatory and fibrotic HRCT lesions. The quantification of FDG uptake extent might be useful to predict functional improvement under treatment.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Jacquelin V, Mekinian A, Brillet PY, et al. FDG-PET/CT in the prediction of pulmonary function improvement in nonspecific interstitial pneumonia. A Pilot Study. Eur J Radiol. 2016. PMID: 27842667. doi:10.1016/j.ejrad.2016.10.001

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。