文献速递胸部技术与安全US

使用角度无关M型超声评估膈肌位移

Use of Angle-Independent M-Mode Sonography for Assessment of Diaphragm Displacement.
PubMed 文献 · J Ultrasound Med · 2016-10-25

研究纳入50名健康成人,在60%最大吸气量下用常规与角度无关M型超声测量双侧膈肌位移。角度无关M型对左侧膈肌可评估率92%,高于常规M型的70%,且双侧位移测值均低于常规M型;右侧两种方法均可评估。

要点

  • 角度无关M型超声对左侧膈肌可评估率92%,常规M型仅70%。
  • 角度无关M型测得的双侧膈肌位移均低于常规M型。
  • 常规M型左右侧位移存在差异,角度无关M型未见侧别差异。

核心结论

  • 角度无关M型超声能更好地显示和评估左侧膈肌,其记录的双侧膈肌位移低于常规M型超声,可能因方向与平移误差更少。

研究设计与样本

  • 研究对比常规M型与角度无关(解剖)M型超声,纳入50名健康成人,在60%最大吸气量(使用吸气量计)下成像双侧半膈。

诊断标准与关键数值

  • 左侧半膈位移常规M型超声成功成像仅70%(n=35),角度无关M型超声可评估92%(n=46)。
  • 右侧半膈位移两种方法均可评估。
  • 右侧位移常规M型均值±SD 4.9±1.4 cm vs 角度无关M型4.6±1.2 cm,P=0.003。
  • 左侧位移常规M型5.4±1.3 cm vs 角度无关M型4.6±1.0 cm,P<0.001。
  • 常规M型左右侧位移平均差0.6±0.2 cm(P=0.005),一致性仅轻度(R²=0.35,P<0.001);角度无关M型左右侧平均差0.1±0.1 cm(P=0.47),一致性良好(R²=0.76,P<0.001)。

局限性

  • 作者指出未来需在膈肌功能障碍人群中评估角度无关M型超声的临床效用。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Sonographic assessment of diaphragm displacement has conventionally been conducted with M-mode sonography via an anterior subcostal approach. This method is subject to measurement errors when diaphragm displacement is not in line with the M-mode plane. We aimed to compare measurements obtained by offline angle-independent (anatomic) M-mode sonography with conventional M-mode sonography.

METHODS: Fifty healthy adults were imaged with conventional and angle-independent M-mode sonography of the bilateral hemidiaphragms at 60% maximal inspiratory capacity using an inspiratory spirometer.

RESULTS: Left hemidiaphragm displacement was successfully imaged by conventional M-mode sonography in only 70% (n = 35), as lung expansion obscured imaging, whereas 92% (n = 46) were assessable by angle-independent M-mode sonography. All right hemidiaphragm displacement could be assessed. Conventional M-mode results were higher than angle-independent M-mode results on the right (mean ± SD, 4.9 ± 1.4 versus 4.6 ± 1.2 cm, respectively; P= .003) and left (5.4 ± 1.3 versus 4.6 ± 1.0 cm; P < .001). Displacement values were different for right versus left hemidiaphragms on conventional M-mode sonography (mean difference, 0.6 ± 0.2 cm; P = .005), with only mild agreement (R2 = 0.35; P < .001). There was no laterality seen in the diaphragm displacement on angle-independent M-mode sonography (mean difference, 0.1 ± 0.1 cm; P = .47), with good agreement (R2 = 0.76; P < .001).

CONCLUSIONS: Angle-independent M-mode sonography leads to better visualization and assessment of the left hemidiaphragm. It records lower displacement than conventional M-mode sonography in the bilateral diaphragms, likely because of fewer orientation and translation errors. Future study is indicated to assess the clinical utility of angle-independent M-mode sonography in a population with diaphragm dysfunction.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Orde SR, Boon AJ, Firth DG, et al. Use of Angle-Independent M-Mode Sonography for Assessment of Diaphragm Displacement. J Ultrasound Med. 2016. PMID: 27872418

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。