文献速递神经CT

脑双能CT:DECT血管成像衍生的虚拟平扫图像与真实平扫图像在颅内出血检测中的比较

Dual-energy CT of the brain: Comparison between DECT angiography-derived virtual unenhanced images and true unenhanced images in the detection of intracranial haemorrhage.
PubMed 文献 · Eur Radiol · 2016-11-23

纳入67例有颅内出血和67例无颅内出血的患者,比较虚拟平扫(VNC)与真实平扫(TNC)图像对颅内出血的检测效能。VNC检测各型颅内出血的敏感度为0.90-1,特异度为0.97-1,但出血显示清晰度显著低于TNC(p<0.001),且11.9%的病例出血范围被低估。

要点

  • VNC图像检测颅内出血的敏感度为0.90-1,特异度为0.97-1。
  • VNC图像上出血显示清晰度显著低于TNC图像(p<0.001)。
  • 11.9%的病例在VNC图像上出血范围被定性低估。

核心结论

  • VNC图像检测颅内出血准确,出血在VNC图像上显示清晰度较低且范围可能被低估。

研究设计与样本

  • 连续纳入67例有颅内出血和67例无颅内出血的患者,均行脑平扫CT和DECT血管成像,由两名放射科医师独立评估VNC与TNC图像。

关键影像表现/征象

  • TNC图像上67例患者共检测到116处不同出血。
  • VNC图像上出血显示清晰度平均值显著低于TNC图像(两名阅片者均p<0.001)。

诊断标准与关键数值

  • VNC检测颅内出血的敏感度按出血类型为0.90-1,特异度为0.97-1。
  • VNC与TNC图像间出血体积无统计学显著差异。
  • VNC图像评估的观察者间一致性为0.86-1.00,TNC图像为0.98-1.00。

临床应用与阅片要点

  • VNC图像检测颅内出血具有高敏感度和特异度,但出血显示清晰度较低且11.9%的病例出血范围被低估。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To evaluate the diagnostic performance of virtual non-contrast (VNC) images in detecting intracranial haemorrhages (ICHs).

METHODS: Sixty-seven consecutive patients with and 67 without ICH who underwent unenhanced brain CT and DECT angiography were included. Two radiologists independently evaluated VNC and true non-contrast (TNC) images for ICH presence and type. Inter-observer agreement for VNC and TNC image evaluation was calculated. Sensitivity and specificity of VNC images for ICH detection were calculated using Fisher's exact test. VNC and TNC images were compared for ICH extent (qualitatively and quantitatively) and conspicuity assessment.

RESULTS: On TNC images 116 different haemorrhages were detected in 67 patients. Inter-observer agreement ranged from 0.98-1.00 for TNC images and from 0.86-1.00 for VNC images. VNC sensitivity ranged from 0.90-1, according to the different ICH types, and specificity from 0.97-1. Qualitatively, ICH extent was underestimated on VNC images in 11.9% of cases. Haemorrhage volume did not show statistically significant differences between VNC and TNC images. Mean haemorrhage conspicuity was significantly lower on VNC images than on TNC images for both readers (p < 0.001).

CONCLUSION: VNC images are accurate for ICH detection. Haemorrhages are less conspicuous on VNC images and their extent may be underestimated.

KEY POINTS: • VNC images represent a reproducible tool for detecting ICH. • ICH can be identified on VNC images with high sensitivity and specificity. • Intracranial haemorrhages are less conspicuous on VNC images than on TNC images. • Intracranial haemorrhages extent may be underestimated on VNC images.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Bonatti M, Lombardo F, Zamboni GA, et al. Dual-energy CT of the brain: Comparison between DECT angiography-derived virtual unenhanced images and true unenhanced images in the detection of intracranial haemorrhage. Eur Radiol. 2016. PMID: 27882426. doi:10.1007/s00330-016-4658-y

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。