放射性损伤与复发性脑转移瘤:结合纹理特征影像组学分析与标准参数可在无需动态扫描的情况下提高18F-FET PET准确率
本研究纳入47例脑转移瘤放疗后MRI对比增强病灶患者(共54个病灶),行动态18F-FET PET,评估TBR及62个纹理参数。TBRmean单独诊断准确率81%,联合Coarseness或Short-zone emphasis升至85%;TBRmax单独83%,联合纹理参数升至85%;TAC模式单独70%,联合TBRmax升至83%。纹理特征联合TBR可能提高鉴别复发性脑转移瘤与放射性损伤的准确率,且无需动态扫描。
要点
- TBRmean单独诊断准确率81%,联合Coarseness或Short-zone emphasis纹理参数后升至85%。
- TBRmax单独诊断准确率83%,联合Coarseness、Short-zone emphasis或Correlation后升至85%。
- TAC模式单独诊断准确率70%,联合TBRmax后升至83%,但纹理特征分析无需动态采集。
核心结论
- 纹理特征分析联合TBR可能提高鉴别复发性脑转移瘤与放射性损伤的诊断准确率,且无需动态18F-FET PET扫描。
研究设计与样本
- 研究纳入47例脑转移瘤放疗后MRI对比增强病灶患者(共54个病灶),行动态18F-FET PET,在注射后20-40分钟 summed 图像上测定TBR及62个纹理参数,并评估注射后0-50分钟动态数据的TTP和TAC模式。
关键影像表现/征象
- MRI上表现为对比增强脑病灶,18F-FET PET上测定肿瘤-脑比值(TBR)及纹理参数。
- 动态PET数据评估达峰时间(TTP)和时间-活性曲线(TAC)模式。
诊断标准与关键数值
- TBRmean单独诊断准确率81%,联合Coarseness或Short-zone emphasis后升至85%。
- TBRmax单独诊断准确率83%,联合Coarseness、Short-zone emphasis或Correlation后升至85%。
- TAC模式单独诊断准确率70%,联合TBRmax后升至83%。
临床应用与阅片要点
- 纹理特征分析联合TBR可能有助于鉴别复发性脑转移瘤与放射性损伤,且无需动态18F-FET PET采集。
- 纹理特征分析提供肿瘤异质性的定量信息。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: We investigated the potential of textural feature analysis of O-(2-[18F]fluoroethyl)-L-tyrosine (18F-FET) PET to differentiate radiation injury from brain metastasis recurrence.
METHODS: Forty-seven patients with contrast-enhancing brain lesions (n = 54) on MRI after radiotherapy of brain metastases underwent dynamic 18F-FET PET. Tumour-to-brain ratios (TBRs) of 18F-FET uptake and 62 textural parameters were determined on summed images 20-40 min post-injection. Tracer uptake kinetics, i.e., time-to-peak (TTP) and patterns of time-activity curves (TAC) were evaluated on dynamic PET data from 0-50 min post-injection. Diagnostic accuracy of investigated parameters and combinations thereof to discriminate between brain metastasis recurrence and radiation injury was compared.
RESULTS: Diagnostic accuracy increased from 81 % for TBRmean alone to 85 % when combined with the textural parameter Coarseness or Short-zone emphasis. The accuracy of TBRmax alone was 83 % and increased to 85 % after combination with the textural parameters Coarseness, Short-zone emphasis, or Correlation. Analysis of TACs resulted in an accuracy of 70 % for kinetic pattern alone and increased to 83 % when combined with TBRmax.
CONCLUSIONS: Textural feature analysis in combination with TBRs may have the potential to increase diagnostic accuracy for discrimination between brain metastasis recurrence and radiation injury, without the need for dynamic 18F-FET PET scans.
KEY POINTS: • Textural feature analysis provides quantitative information about tumour heterogeneity • Textural features help improve discrimination between brain metastasis recurrence and radiation injury • Textural features might be helpful to further understand tumour heterogeneity • Analysis does not require a more time consuming dynamic PET acquisition.
引用
- Lohmann P, Stoffels G, Ceccon G, et al. Radiation injury vs. recurrent brain metastasis: combining textural feature radiomics analysis and standard parameters may increase 18F-FET PET accuracy without dynamic scans. Eur Radiol. 2016. PMID: 27853813. doi:10.1007/s00330-016-4638-2
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。