应用扩散张量和扩散峰度成像评估组织异质性进行胶质瘤分级
回顾性纳入53例WHO II级(19例)、III级(20例)、IV级(14例)胶质瘤患者,在T2加权图像上勾画ROI并在扩散参数图上计算熵和繁忙度纹理指标及基于互相关的体积异质性指数,发现除部分各向异性和峰度各向异性外,各扩散参数的纹理指标和体积异质性指数在组间有显著差异,提示利用DTI和DKI的肿瘤异质性指标有望实现胶质瘤自动分级。
要点
- MD的熵在II vs III级P=0.029、III vs IV级P=0.0312,为DTI中区分度最高者。
- MK的熵在II vs III级P=0.018、III vs IV级P=0.022,为DKI中区分度最高者。
- 基于互相关的体积异质性指数在MD上II vs III级P=0.0002、III vs IV级P=0.0003。
核心结论
- 在DTI和DKI参数上应用肿瘤异质性指标对胶质瘤分级展现出很大潜力,有望实现自动分级。
研究设计与样本
- 回顾性研究纳入53例胶质瘤患者,WHO II级19例、III级20例、IV级14例;由专家在T2加权图像上勾画覆盖肿瘤的感兴趣区,在扩散参数图上计算统计纹理指标(熵、繁忙度),并采用互相关分析提出体积异质性指数;采用Mann-Whitney检验比较组间差异,并以ROC分析评估诊断准确性。
诊断标准与关键数值
- MD的熵在II vs III级P=0.029、III vs IV级P=0.0312;MD的繁忙度在II vs III级P=0.0421、III vs IV级P=0.0415。
- MK的熵在II vs III级P=0.018、III vs IV级P=0.022;MK的繁忙度在II vs III级P=0.038、III vs IV级P=0.04。
- 体积异质性指数在MD上II vs III级P=0.0002、III vs IV级P=0.0003;在MK上II vs III级P=0.0001、III vs IV级P=0.0003。
临床应用与阅片要点
- 原文结论认为在DTI和DKI参数上应用肿瘤异质性指标对胶质瘤分级展现出很大潜力,有望实现自动分级。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
INTRODUCTION: In this work, we aim to assess the significance of diffusion tensor imaging (DTI) and diffusion kurtosis imaging (DKI) parameters in grading gliomas.
METHODS: Retrospective studies were performed on 53 subjects with gliomas belonging to WHO grade II (n = 19), grade III (n = 20) and grade IV (n = 14). Expert marked regions of interest (ROIs) covering the tumour on T2-weighted images. Statistical texture measures such as entropy and busyness calculated over ROIs on diffusion parametric maps were used to assess the tumour heterogeneity. Additionally, we propose a volume heterogeneity index derived from cross correlation (CC) analysis as a tool for grading gliomas. The texture measures were compared between grades by performing the Mann-Whitney test followed by receiver operating characteristic (ROC) analysis for evaluating diagnostic accuracy.
RESULTS: Entropy, busyness and volume heterogeneity index for all diffusion parameters except fractional anisotropy and anisotropy of kurtosis showed significant differences between grades. The Mann-Whitney test on mean diffusivity (MD), among DTI parameters, resulted in the highest discriminability with values of P = 0.029 (0.0421) for grade II vs. III and P = 0.0312 (0.0415) for III vs. IV for entropy (busyness). In DKI, mean kurtosis (MK) showed the highest discriminability, P = 0.018 (0.038) for grade II vs. III and P = 0.022 (0.04) for III vs. IV for entropy (busyness). Results of CC analysis illustrate the existence of homogeneity in volume (uniformity across slices) for lower grades, as compared to higher grades. Hypothesis testing performed on volume heterogeneity index showed P values of 0.0002 (0.0001) and 0.0003 (0.0003) between grades II vs. III and III vs. IV, respectively, for MD (MK).
CONCLUSION: In summary, the studies demonstrated great potential towards automating grading gliomas by employing tumour heterogeneity measures on DTI and DKI parameters.
引用
- Raja R, Sinha N, Saini J, et al. Assessment of tissue heterogeneity using diffusion tensor and diffusion kurtosis imaging for grading gliomas. Neuroradiology. 2016. PMID: 27796448
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。