文献速递神经外周血管MRDSA

首过对比增强MR血管成像评估治疗后脊髓动静脉瘘:是否还需导管血管造影?

First-Pass Contrast-Enhanced MR Angiography in Evaluation of Treated Spinal Arteriovenous Fistulas: Is Catheter Angiography Necessary?
PubMed 文献 · AJNR Am J Neuroradiol · 2016-11-03

回顾性分析22例脊髓动静脉瘘及1例颅内动静脉瘘治疗后患者共28组MR/MRA与DSA配对检查,评估首过对比增强MRA诊断复发/残留瘘的效能。MRA诊断敏感度100%、特异度95%(P < .001),定位全部正确且观察者间无分歧;常规MR参数与复发/残留无显著关联。作者认为首过MRA可能替代DSA用于治疗后随访。

要点

  • 首过对比增强MRA诊断治疗后复发/残留脊髓动静脉瘘敏感度100%、特异度95%。
  • MRA对复发/残留瘘的椎体水平定位全部正确,两位阅片者间无分歧。
  • 常规MR参数(髓内T2高信号、髓周蛇形流空、脊髓强化)与复发/残留无显著关联。

核心结论

  • 首过对比增强MRA对识别复发/残留脊髓动静脉瘘具有高敏感度和特异度,可能替代DSA用于脊髓动静脉瘘治疗后的随访。

研究设计与样本

  • 回顾性研究,纳入2000年1月至2015年4月本三级转诊医院接受手术和/或血管内治疗脊髓动静脉瘘后行脊柱MR、首过对比增强MRA及DSA的患者,共22例脊髓动静脉瘘和1例颅内动静脉瘘(既往有颈段髓周静脉引流)的28组治疗后MR/MRA与DSA配对检查;以DSA为参考标准,由2名经验丰富的神经放射科医生在不知DSA结果的情况下评估MRA复发/残留瘘及其椎体水平。

关键影像表现/征象

  • 常规MR评估内容包括髓内T2高信号、髓周蛇形流空和脊髓强化,这些常规MR参数与复发/残留脊髓动静脉瘘无显著关联。

诊断标准与关键数值

  • 以DSA为参考标准,MRA诊断复发/残留瘘的敏感度100%、特异度95%(P < .001),5例患者6组图像DSA显示复发/残留病变,MRA全部正确识别并有1例假阳性,所有病例定位正确且观察者间无分歧。

临床应用与阅片要点

  • 首过对比增强MRA可用于脊髓动静脉瘘治疗后的随访评估,识别复发/残留瘘并定位椎体水平;常规MR参数与复发/残留无显著关联,阅片时不能仅凭常规MR表现判断。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: Catheter angiography is typically used for follow-up of treated spinal AVFs. The purpose of this study was to determine the diagnostic performance and utility of first-pass contrast-enhanced MRA in the posttreatment evaluation of spinal AVFs compared with DSA.

MATERIALS AND METHODS: A retrospective review was performed of all patients at our tertiary referral hospital (from January 2000 to April 2015) who underwent spine MR imaging, first-pass contrast-enhanced MRA, and DSA after surgical and/or endovascular treatment of a spinal AVF. Presence of recurrent or residual fistula on MRA, including vertebral level of the recurrent/residual fistula, was evaluated by 2 experienced neuroradiologists blinded to DSA findings. Posttreatment conventional MR imaging findings were also evaluated, including presence of intramedullary T2 hyperintensity, perimedullary serpentine flow voids, and cord enhancement. The performance of MRA and MR imaging findings for diagnosis of recurrent/residual fistula was determined by using DSA as the criterion standard.

RESULTS: In total, 28 posttreatment paired MR imaging/MRA and DSA studies were evaluated in 22 patients with prior spinal AVF and 1 patient with intracranial AVF with prior cervical perimedullary venous drainage. Six image sets of 5 patients demonstrated recurrent/residual disease at DSA. MRA correctly identified all cases with recurrent/residual disease with 1 false-positive (sensitivity, 100%; specificity 95%; P < .001), with correct localization in all cases without interobserver disagreement. Conventional MR imaging parameters were not significantly associated with recurrent/residual spinal AVF.

CONCLUSIONS: First-pass MRA demonstrates high sensitivity and specificity for identifying recurrent/residual spinal AVFs and may potentially substitute for DSA in the posttreatment follow-up of patients with spinal AVFs.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Mathur S, Symons SP, Huynh TJ, et al. First-Pass Contrast-Enhanced MR Angiography in Evaluation of Treated Spinal Arteriovenous Fistulas: Is Catheter Angiography Necessary? AJNR Am J Neuroradiol. 2016. PMID: 27811131. doi:10.3174/ajnr.A4971

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。