文献速递神经介入MRDSA

颅内动脉瘤血管内治疗后弥散加权成像检出的缺血性病灶:系统综述与Meta分析

Diffusion-Weighted Imaging-Detected Ischemic Lesions following Endovascular Treatment of Cerebral Aneurysms: A Systematic Review and Meta-Analysis.
PubMed 文献 · AJNR Am J Neuroradiol · 2016-11-17

该系统综述与Meta分析纳入2000年至2016年4月间22项研究、2148例患者和2268个动脉瘤,评估颅内动脉瘤血管内治疗后DWI阳性血栓栓塞事件的发生率。总体发生率为49%(95%CI 42%-56%),血流导向装置治疗较单纯弹簧圈栓塞有更高的DWI阳性病灶发生率趋势(67% vs 45%,P=0.07),性别、动脉瘤破裂状态、位置和大小与DWI阳性病灶率无关。

要点

  • 颅内动脉瘤血管内治疗后约半数患者DWI可见血栓栓塞性缺血病灶,总体发生率49%(95%CI 42%-56%)。
  • 血流导向装置治疗后DWI阳性病灶率67%(95%CI 46%-85%),单纯弹簧圈栓塞为45%(95%CI 33%-56%),两者差异未达统计学显著(P=0.07)。
  • 性别、动脉瘤破裂状态、位置和大小与DWI阳性血栓栓塞事件无关联。

核心结论

  • 约半数患者颅内动脉瘤血管内治疗后DWI可见梗死灶;血流导向装置治疗较单纯弹簧圈栓塞有更高的DWI阳性病灶发生率趋势;患者人口学特征和动脉瘤特征与DWI阳性血栓栓塞事件无关。

研究设计与样本

  • 系统综述与Meta分析,检索2000年至2016年4月发表的报道颅内动脉瘤血管内治疗后DWI表现的研究,纳入22项研究、2148例患者和2268个动脉瘤,采用随机效应模型进行Meta分析。

关键影像表现/征象

  • 血管内治疗后DWI阳性血栓栓塞事件总体发生率为49%(95%CI 42%-56%)。
  • 血流导向装置治疗后DWI阳性病灶率为67%(95%CI 46%-85%),单纯弹簧圈栓塞为45%(95%CI 33%-56%),血流导向装置组有更高趋势(P=0.07)。
  • 球囊辅助弹簧圈栓塞组DWI阳性病灶率为44%(95%CI 29%-60%),与单纯弹簧圈栓塞组无差异(P=0.99)。
  • 支架辅助弹簧圈栓塞组DWI阳性病灶率为43%(95%CI 24%-63%),与单纯弹簧圈栓塞组无差异(P=0.89)。

诊断标准与关键数值

  • 主要结局为DWI阳性血栓栓塞事件的发生率,以DWI检出缺血病灶为判定依据。
  • 总体DWI阳性血栓栓塞事件发生率49%(95%CI 42%-56%)。
  • 血流导向装置67%(95%CI 46%-85%)vs 单纯弹簧圈栓塞45%(95%CI 33%-56%),P=0.07。
  • 球囊辅助弹簧圈栓塞44%(95%CI 29%-60%)vs 单纯弹簧圈栓塞,P=0.99;支架辅助弹簧圈栓塞43%(95%CI 24%-63%)vs 单纯弹簧圈栓塞,P=0.89。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: Endovascular treatment of intracranial aneurysms is associated with the risk of thromboembolic ischemic complications. Many of these events are asymptomatic and identified only on diffusion-weighted imaging. We performed a systematic review and meta-analysis to study the incidence of DWI positive for thromboembolic events following endovascular treatment of intracranial aneurysms.

MATERIALS AND METHODS: A comprehensive literature search identified studies published between 2000 and April 2016 that reported postprocedural DWI findings in patients undergoing endovascular treatment of intracranial aneurysms. The primary outcome was the incidence of DWI positive for thromboembolic events. We examined outcomes by treatment type, sex, and aneurysm characteristics. Meta-analyses were performed by using a random-effects model.

RESULTS: Twenty-two studies with 2148 patients and 2268 aneurysms were included. The overall incidence of DWI positive for thromboembolic events following endovascular treatment was 49% (95% CI, 42%-56%). Treatment with flow diversion trended toward a higher rate of DWI positive for lesions than coiling alone (67%; 95% CI, 46%-85%; versus 45%; 95% CI, 33%-56%; P = .07). There was no difference between patients treated with coiling alone and those treated with balloon-assisted (44%; 95% CI, 29%-60%; P = .99) or stent-assisted (43%; 95% CI, 24%-63%; P = .89) coiling. Sex, aneurysm rupture status, location, and size were not associated with the rate of DWI positive for lesions.

CONCLUSIONS: One in 2 patients may have infarcts on DWI following endovascular treatment of intracranial aneurysms. There is a trend toward a higher incidence of DWI-positive lesions following treatment with flow diversion compared with coiling. Patient demographics and aneurysm characteristics were not associated with DWI-positive thromboembolic events.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。