文献速递神经儿科影像MR

儿童合成脑MRI的临床验证:初步经验

Clinical validation of synthetic brain MRI in children: initial experience.
PubMed 文献 · Neuroradiology · 2016-11-26

研究纳入32例接受常规与合成序列脑MRI的患儿(22例异常),4名盲法阅片者间隔平均33天对合成与常规检查分别书写报告。合成与常规检查总体一致率97%,与共识判读一致率分别为81%和84%(P=0.61),特定征象的敏感度、特异度、准确率及图像质量、诊断信心均无显著差异。

要点

  • 合成序列与常规序列总体一致率达97%,与共识判读一致率合成81% vs 常规84%(P=0.61)。
  • 脑室、脑脊液、脑实质及血管等特定征象的敏感度、特异度、准确率在两种序列间无显著差异(P>0.05)。
  • 图像质量、诊断信心及噪声/伪影在合成与常规序列间无显著差异。

核心结论

  • 作为标准儿童脑部检查的一部分,合成生成序列的诊断准确性和质量与常规采集序列相当;需要在更大规模研究中进一步确认。

研究设计与样本

  • 单中心前瞻性临床验证研究,32例患儿接受常规与合成序列脑MRI(22例异常),合成轴向T1、T2及T2液体衰减反转恢复或质子密度加权序列匹配相应临床序列。

诊断标准与关键数值

  • 合成与常规检查总体一致率97%;与共识判读一致率常规84% vs 合成81%(P=0.61);脑室、脑脊液、脑实质及血管相关特定征象的敏感度、特异度、准确率在两种序列间无显著差异(P>0.05)。

临床应用与阅片要点

  • 作者认为合成序列的诊断准确性和质量与常规采集序列相当,可在标准儿童脑部检查中作为常规序列的替代选择。

局限性

  • 原文在结论中写明需要在更大规模研究中进一步确认。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

INTRODUCTION: The purpose of this study was to determine the diagnostic accuracy of synthetic MR sequences generated through post-acquisition processing of a single sequence measuring inherent R1, R2, and PD tissue properties compared with sequences acquired conventionally as part of a routine clinical pediatric brain MR exam.

METHODS: Thirty-two patients underwent routine clinical brain MRI with conventional and synthetic sequences acquired (22 abnormal). Synthetic axial T1, T2, and T2 fluid attenuation inversion recovery or proton density-weighted sequences were made to match the comparable clinical sequences. Two exams for each patient were de-identified. Four blinded reviewers reviewed eight patients and were asked to generate clinical reports on each exam (synthetic or conventional) at two different time points separated by a mean of 33 days. Exams were rated for overall and specific finding agreement (synthetic/conventional and compared to gold standard consensus review by two senior reviewers with knowledge of clinical report), quality, and diagnostic confidence.

RESULTS: Overall agreement between conventional and synthetic exams was 97%. Agreement with consensus readings was 84% (conventional) and 81% (synthetic), p = 0.61. There were no significant differences in sensitivity, specificity, or accuracy for specific imaging findings involving the ventricles, CSF, brain parenchyma, or vasculature between synthetic or conventional exams (p > 0.05). No significant difference in exam quality, diagnostic confidence, or noise/artifacts was noted comparing studies with synthetic or conventional sequences.

CONCLUSIONS: Diagnostic accuracy and quality of synthetically generated sequences are comparable to conventionally acquired sequences as part of a standard pediatric brain exam. Further confirmation in a larger study is warranted.

来源:Neuroradiology,查看原文。版权归原作者所有。

引用

  1. West H, Leach JL, Jones BV, et al. Clinical validation of synthetic brain MRI in children: initial experience. Neuroradiology. 2016. PMID: 27889836. doi:10.1007/s00234-016-1765-z

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。