文献速递骨肌技术与安全US

标准化双平面超声动态剪辑对冈上肌腱病变的诊断效能与可重复性

Diagnostic performance and reproducibility of standardized two-plane ultrasound cine clips for supraspinatus tendon pathology.
PubMed 文献 · Skeletal Radiol · 2026-10-31

这项前瞻性单中心研究纳入140例肩部超声检查,由两名肌骨放射科医师独立盲法审阅标准化冈上肌腱纵向及横向动态剪辑,以当日临床超声报告为参考标准。结果显示动态剪辑对全层撕裂诊断效能高(敏感度87%、特异度98%),观察者间κ为0.95;但对部分层撕裂敏感度低(57%),对肌腱病特异度低(28%),提示动态剪辑不能替代完整实时超声检查。

要点

  • 标准化双平面动态剪辑对冈上肌腱全层撕裂诊断效能高,观察者间一致性极好(κ=0.95)。
  • 部分层撕裂敏感度低(57%),肌腱病特异度低(28%),动态剪辑不足以单独诊断这些病变。
  • 动态剪辑应作为完整实时肩部超声检查的补充,而非替代。

诊断标准与关键数值

  • 读者1对全层撕裂敏感度87%(95%CI 69-96%)、特异度98%(92-100%);对完全撕裂敏感度73%(39-94%)、特异度97%(92-99%)。
  • 读者1对钙化性肌腱病敏感度79%、特异度85%;对部分层撕裂敏感度57%、特异度87%;对肌腱病敏感度92%、特异度28%。
  • 读者2对全层撕裂敏感度92%(64-100%),对部分层撕裂敏感度18%(2-52%)。
  • 读者内κ范围0.17(肌腱病)至0.89(全层撕裂);观察者间κ全层撕裂0.95、完全撕裂0.56、部分层撕裂0.21。

局限性

  • 单中心前瞻性研究,样本量有限。
  • 以临床超声报告为参考标准,非手术或MRI对照。
  • 读者2仅阅读51例,部分诊断效能估计不精确。
  • 部分层撕裂和肌腱病的诊断效能不足,动态剪辑的临床应用受限。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To determine the diagnostic performance and reader reproducibility of standardized two-plane cine clips for supraspinatus tendon pathology, using the complete radiologist-supervised shoulder ultrasound examination as the clinical reference standard.

MATERIALS AND METHODS: This prospective single-centre study screened 140 consecutive shoulder ultrasound examinations. Standardized longitudinal and transverse supraspinatus cine clips were independently reviewed by two fellowship-trained musculoskeletal radiologists blinded to the clinical report. Reader 1 read all included examinations (24 twice); Reader 2 read 51. Diagnostic performance (exact 95% confidence intervals) was calculated against the same-day clinical ultrasound report, and reliability with Cohen's κ. Reporting radiologists could access the standardized clips.

RESULTS: Of 140 examinations, 114 were analyzed (mean age 57 years; 56 women). Reader 1 showed high performance for full-thickness tears (sensitivity 87% [95% confidence interval 69-96%], specificity 98% [92-100%]) and complete tears (sensitivity 73% [39-94%], specificity 97% [92-99%]). Calcific tendinopathy yielded sensitivity/specificity of 79%/85%; partial-thickness tears, 57%/87%; and tendinopathy, 92%/28%. Reader 2 sensitivity was 92% [64-100%] for full-thickness and 18% [2-52%] for partial-thickness tears. Intra-observer κ ranged from 0.17 (tendinopathy) to 0.89 (full-thickness tears). Inter-observer κ was 0.95 for full-thickness, 0.56 for complete and 0.21 for partial-thickness tears.

CONCLUSION: Standardized two-plane cine clips demonstrate high diagnostic performance and inter-observer reliability for full-thickness supraspinatus tears. For complete tears, inter-observer agreement was moderate and sensitivity was imprecise. Given limited sensitivity for partial-thickness tears and low specificity for tendinopathy, cine clips alone are insufficient for these pathologies and should complement rather than replace complete real-time shoulder ultrasound examinations.

来源:Skeletal Radiol,查看原文。版权归原作者所有。