经颅超声应用中鼠脑血管光声成像的数值优化
本研究通过三维蒙特卡罗模拟评估小鼠脑经颅光传播,优化临床前光声成像监测系统参数。确定长轴侧向照明最佳波长890-1030 nm、入射角12°-63°,标准暗场照明波长890-1030 nm、入射角10°-50°,所得光声图像信噪比达28.1 dB。血管模拟体模分辨率分析显示横向约160 μm、轴向约100 μm,表明系统可检测血脑屏障开放监测中的细小血管结构。
要点
- 标准暗场照明下980 nm波长、25°入射角是临床前经颅光声成像的理想商用选项。
- 优化后光声图像信噪比最高28.1 dB,横向分辨率约160 μm、轴向约100 μm。
- 光声成像可在不干扰治疗声场的情况下监测血脑屏障开放动态过程。
关键影像表现/征象
- 长轴侧向照明最佳近红外波长范围为890-1030 nm,入射角范围为12°-63°。
- 标准暗场照明最佳近红外波长范围为890-1030 nm,入射角范围为10°-50°。
- 所得光声图像信噪比最高达28.1 dB。
- 血管模拟体模显示横向分辨率约160 μm、轴向分辨率约100 μm。
诊断标准与关键数值
- 标准暗场照明下980 nm波长与25°入射角为理想商用选项。
- 光声图像信噪比最高28.1 dB。
- 横向分辨率约160 μm、轴向分辨率约100 μm。
临床应用与阅片要点
- 经颅光声监测血脑屏障开放时优先考虑标准暗场照明、980 nm波长、25°入射角配置。
- 分辨率约160 μm(横向)和100 μm(轴向)提示可检测细小血管结构,阅片时注意该尺度下限。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: Focused ultrasound (FUS) combined with microbubbles can locally and transiently open the blood-brain barrier (BBB), allowing enhanced drug delivery into the brain. During treatment, monitoring techniques are required to identify BBB disruption and downstream effects. Photoacoustic imaging (PAI), as a high contrast and high spatial resolution imaging modality, provides the capability to visualize dynamic processes during therapy, without interfering with the therapeutic acoustic field. The objective of this study was to evaluate transcranial light propagation in the mouse brain and define the optimal characteristics of a preclinical PAI monitoring system.
METHODS: We performed 3D Monte Carlo simulations to evaluate transcranial light propagation in the mouse brain. After determining the optimal optical parameters and acquiring optical fluence in the mouse brain, we conducted photoacoustic (PA) reconstruction to obtain PAI of the cerebral blood vessels.
RESULTS: We numerically determined the optimal near-infrared (NIR) wavelength range (890-1030 nm) and incident angle range (12°-63°) for long-axis lateral illumination, as well as the wavelength range (890-1030 nm) and incident angle range (10°-50°) for standard dark-field illumination, to optimize PAI during therapeutic ultrasound exposure. The resulting PAI had a signal-to-noise ratio of up to 28.1 dB. Furthermore, resolution analysis using vessel-mimicking phantoms demonstrated lateral and axial resolutions of approximately 160 μm and 100 μm, respectively, highlighting the system's capability to detect fine vessel-mimicking structures during BBB-opening monitoring.
CONCLUSION: Our findings indicate that a wavelength of 980 nm with an incidence angle of 25° under standard dark-field illumination is an ideal commercially available option for preclinical implementation of transcranial PAI in mouse models.