基于CT的多模态融合模型用于术前透明细胞肾细胞癌分级:一项多中心研究
该回顾性多中心研究纳入1052例经组织学证实的ccRCC患者,基于CMP期CECT提取临床、深度学习和多尺度影像组学特征构建融合模型,用于术前WHO/ISUP低级别与高级别分类。加权软投票模型在内外部验证集的AUC分别为0.761和0.745,判别性能中等,SHAP分析显示瘤周5mm影像组学特征贡献最大。
要点
- 融合模型术前区分ccRCC WHO/ISUP低/高级别的AUC内部0.761、外部0.745,性能中等。
- 瘤周5mm影像组学特征是模型输出的首要决定因素,其次为瘤内影像组学特征。
- 深度学习与临床特征相对贡献较低,提示影像组学特征在分级中占主导。
英文原文(摘要)· 点击展开
OBJECTIVES: To develop and evaluate a multimodal fusion framework for the preoperative World Health Organization/International Society of Urological Pathology (WHO/ISUP) low- and high-grade classification of clear cell renal cell carcinoma (ccRCC), integrating clinical characteristics, deep learning (DL), and radiomic signatures extracted from corticomedullary phase (CMP) contrast-enhanced computed tomography (CECT) images.
MATERIALS AND METHODS: In this retrospective multicenter study, we evaluated a cohort of 1,052 patients with histologically verified ccRCC across four institutions. The data of the primary cohort (Center A, n = 665) were randomly divided into a training dataset (n = 465) and an internal validation dataset (n = 200). The data of 387 additional patients from three institutions (Centers B-D) constituted the independent external test set. Initial single-modality classifiers were developed via ensemble machine learning, utilizing clinical variables, multiscale radiomic data (capturing intratumoral, habitat, and peritumoral regions), and DL representations (2D, 2.5D, and 3D). A soft voting mechanism was subsequently applied to integrate the top-performing base models. Model interpretability was determined using SHapley Additive exPlanations (SHAP) values, and overall diagnostic efficacy was quantified through receiver operating characteristic (ROC) curve analysis.
RESULTS: The weighted soft voting model (SoftVote-Opt) showed the numerically highest AUC among the evaluated fusion strategies and single-modality models. This model yielded AUCs of 0.761 (95 % CI: 0.675-0.839) and 0.745 (95 % CI: 0.675-0.813), with corresponding MCCs of 0.347 (95 % CI: 0.217-0.475) and 0.302(95 % CI: 0.205 -0.387), within the internal validation and external test sets, respectively. SHAP analysis revealed peritumoral 5 mm radiomic features as the primary determinants of the model's output, followed by intratumoral radiomic features, whereas deep learning and clinical features offered lower relative contributions.
CONCLUSION: The multimodal fusion framework demonstrated moderate discriminatory performance across the internal validation and external test cohorts. These findings could be regarded as an exploratory study rather than evidence of established clinical superiority. The framework may provide complementary information for preoperative ccRCC grading.
CRITICAL RELEVANCE STATEMENT: This study evaluates an exploratory multimodal fusion framework for preoperative ccRCC grading by combining clinical data, deep learning, and multiscale radiomic features. The framework may provide complementary non-invasive information for risk stratification.
引用
- Wu Y, Wang H, Liu C, et al. CT-based multimodal fusion model for preoperative clear cell renal cell carcinoma grading: A multicenter study. Eur J Radiol. 2026. PMID: 42962514. doi:10.1016/j.ejrad.2026.113317
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。