文献速递神经技术与安全CT

能量积分与硅光子计数探测器CT非增强神经图像质量比较

Image Quality of Non-Contrast Neurological Images on Energy-Integrating versus Silicon Photon-Counting Detector CT.
PubMed 文献 · AJNR Am J Neuroradiol · 2026-10-22

本研究回顾性纳入EID-CT受试者,前瞻性纳入原型深硅光子计数探测器CT(dSi-PCCT)受试者,由四名神经放射学家以5分Likert量表评估图像质量。dSi-PCCT联合深度学习重建在锐利度、噪声、灰白质分化及豆状核与岛叶 ribbon 结构信心上显著优于EID-CT,伪影无差异,灰白质CNR无显著差异。

要点

  • dSi-PCCT联合深度学习重建可提升非增强神经CT的锐利度、降低噪声并改善灰白质分化。
  • 豆状核与岛叶 ribbon 的结构信心在dSi-PCCT上更高,有助于早期缺血征象识别。
  • 伪影出现率与灰白质CNR在两种探测器间无统计学差异。
英文原文(摘要)· 点击展开

The purpose of this work was to evaluate image quality of non-contrast neurological CT scans on a commercially available energy-integrating detector (EID) CT compared to a prototype deep silicon (dSi) photon-counting detector CT (PCCT). A cohort of subjects scanned on the EID-CT (Apex CT, GE HealthCare, Waukesha, WI) was retrospectively recruited. A second cohort of prospectively recruited subjects was scanned on the prototype dSi-PCCT CT using deep learning (DL) recon. Image quality was assessed by four neuroradiologists on a 5-point Likert scale for sharpness, noise, and presence of artifacts, differentiation of gray-white matter, and structural confidence in the lentiform nucleus and insular ribbon. Reader agreement was assessed through a linearly weighted Cohen's kappa. Contrast-to-noise ratio (CNR) between gray and white matter was determined. Differences between the median Likert scores and CNRs of the two cohorts were assessed with the Mann-Whitney U test. Reader agreement was fair on average ([Formula: see text]). Median Likert scores of the dSi-PCCT with DL recon cohort were statistically superior compared to the median scores of the EID-CT scores for sharpness, noise, gray-white matter differentiation, and structural confidence of the lentiform nucleus and insular ribbon. No statistical difference was detected in the presence of artifacts between the cohorts. Average CNRs were 1.45±0.14 and 1.53±0.08 for the EID-CT and dSi-PCCT cohorts, respectively, but no significant difference was detected (p = 0.72). Increased sharpness, lower noise, and better ability to differentiate structures demonstrate improved image quality and the potential for utilizing PCCT in non-contrast neurological imaging tasks.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Salyapongse AM, Avey GD, Fink J, et al. Image Quality of Non-Contrast Neurological Images on Energy-Integrating versus Silicon Photon-Counting Detector CT. AJNR Am J Neuroradiol. 2026. PMID: 42914528. doi:10.3174/ajnr.A9689

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。