多普勒超声与CTA在颈动脉狭窄中的不一致性及其对手术决策的潜在影响
回顾性纳入79例DUS检出显著颈动脉狭窄患者,比较DUS与CTA(NASCET及ECST法)分级一致性。DUS与CTA一致性NASCET法为fair(κ=0.413),ECST法为moderate(κ=0.531);不一致最常见于DUS 50-69%狭窄组,且与CTA测量方法有关。联合两种无创影像可能减少手术候选者的误分类。
要点
- DUS与CTA在显著颈动脉狭窄分级上仅呈fair至moderate一致,阅片时需留意方法学差异。
- 不一致最常见于DUS 50-69%狭窄组,该区间报告应谨慎并建议结合CTA复核。
- CTA残余管腔直径在NASCET法不一致病例中显著更大,提示测量方法影响判读。
关键影像表现/征象
- DUS与CTA一致性NASCET法为fair(κ=0.413,p<.001),ECST法为moderate(κ=0.531,p<.001)。
- NASCET与ECST两法之间一致性为substantial(κ=0.799,p<.001)。
- 不一致最常见于DUS 50-69%狭窄组,并随狭窄严重程度和CTA测量方法变化。
- 斑块类型、斑块长度和钙化与不一致无关。
- CTA残余管腔直径在NASCET法不一致病例中显著更大(p=.018),ECST分类下无显著差异。
诊断标准与关键数值
- DUS与CTA狭窄分级一致性:NASCET法κ=0.413(fair),ECST法κ=0.531(moderate)。
- NASCET与ECST两种CTA测量方法间一致性κ=0.799(substantial)。
- 不一致最常见于DUS 50-69%狭窄组。
- NASCET法不一致病例CTA残余管腔直径显著更大(p=.018)。
临床应用与阅片要点
- 对DUS报告50-69%狭窄的患者,建议结合CTA复核以避免手术决策误分类。
- 报告颈动脉狭窄时应注明所用CTA测量方法(NASCET或ECST),因两者一致性仅substantial。
- 斑块类型、长度及钙化与DUS-CTA不一致无关,不应作为解释差异的主要依据。
- 部分患者的不一致可能影响手术决策,联合两种无创影像有助于减少误分类。
局限性
- 回顾性研究设计。
- 单中心、样本量79例。
- 未报告DUS与CTA检查的时间间隔。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: The degree of carotid artery stenosis influences surgical decision-making; therefore, accurate assessment is essential for appropriate patient selection. This study evaluated agreement between Doppler ultrasonography (DUS) and computed tomography angiography (CTA) in patients with significant stenosis detected on DUS and investigated factors associated with discordance.
METHODS: In this retrospective study, 79 patients who underwent DUS between January 2024 and October 2025 were included. DUS stenosis grade, CTA stenosis according to NASCET and ECST methods, lumen diameters, plaque characteristics, and accompanying vascular features were evaluated.
RESULTS: Agreement between DUS and CTA was fair using NASCET (κ = 0.413; p < .001) and moderate using ECST (κ = 0.531; p < .001). Agreement between NASCET and ECST was substantial (κ = 0.799; p < .001). Discordance was most frequent in the 50-69% DUS stenosis group and varied according to stenosis severity and CTA measurement method. Plaque type, plaque length, and calcification were not associated with discordance. Residual lumen diameter on CTA was significantly larger in NASCET-based discordant cases (p = .018) whereas no significant difference was observed using ECST classification. In some patients, discrepancies could potentially affect surgical decision-making.
CONCLUSION: Agreement between DUS and CTA in significant carotid stenosis was fair using NASCET and moderate using ECST, with discordance particularly frequent in the 50-69% stenosis group and dependent on the CTA measurement method. Combined assessment with 2 noninvasive imaging modalities may help reduce misclassification in patients considered for surgical treatment.
引用
- Bayraktar ES. Doppler Ultrasonography and Computed Tomography Angiography in Carotid Artery Stenosis: Discordance and Its Potential Impact on Surgical Decision-Making. J Ultrasound Med. 2026. PMID: 42951589. doi:10.1002/jum.70530
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。