垂体Crooke细胞腺瘤的影像学特征:13例系列分析
本研究回顾性分析13例垂体Crooke细胞腺瘤(CCA)的术前及术后随访MR图像,结合临床和病理资料。结果显示多数肿瘤T1WI等信号、轻度强化,Knosp 1级为最常见鞍旁延伸模式;4例术后进展者术前均见肿瘤邻近颈内动脉壁强化减低。
要点
- CCA多为T1WI等信号、轻度强化,T2WI信号与肿瘤大小相关。
- Knosp 1级是最常见的鞍旁延伸模式,需注意评估。
- 术后进展者术前MRI可见肿瘤邻近颈内动脉壁强化减低。
关键影像表现/征象
- 8例(61.5%)为大腺瘤,5例(38.5%)为微腺瘤。
- T1WI上12例(92.3%)为等信号。
- T2WI上6例(46.2%)为高信号,4例(30.8%)为低信号,3例(23.1%)为等信号。
- 大腺瘤以高信号(5/8)或等信号(3/8)为主,微腺瘤以低信号(4/5)为主。
- 2例大腺瘤(15.4%)见多发微囊变。
临床应用与阅片要点
- 阅片时注意CCA可表现为T1WI等信号、轻度强化,避免漏诊。
- 评估鞍旁延伸时注意Knosp分级,1级常见但需警惕进展。
- 对术后进展风险患者,可关注肿瘤邻近颈内动脉壁强化情况。
局限性
- 样本量小(13例),单中心回顾性研究。
- 颈内动脉壁强化减低的临床意义需更大样本和更长随访验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: Crooke cell adenoma (CCA) is a rare and aggressive subtype of pituitary neuroendocrine tumor (PitNET). This study aimed to characterize the imaging features of CCA.
METHODS: Preoperative and postoperative follow-up MR images of 13 patients with CCA were retrospectively reviewed to characterize their imaging features in conjunction with clinical and pathological findings.
RESULTS: Among the 13 CCAs, 8 (61.5%) were macroadenomas and 5 (38.5%) were microadenomas. On T1-weighted imaging, 12 tumors (92.3%) were isointense. On T2-weighted imaging, 6 (46.2%) were hyperintense, 4 (30.8%) were hypointense, and 3 (23.1%) were isointense. Macroadenomas were predominantly hyperintense (5/8) or isointense (3/8), whereas microadenomas were predominantly hypointense (4/5). Multiple microcystic changes were observed in 2 macroadenomas (15.4%). Mild contrast enhancement was observed in 10 tumors (76.9%). Knosp grade 1 was the most common pattern of parasellar extension (8/13, 61.5%). During postoperative follow-up of 2-39 months, tumor progression occurred in 4 patients (30.8%), all of whom had undergone subtotal resection. Retrospective review of their preoperative contrast-enhanced MRI showed reduced enhancement of the tumor-adjacent internal carotid artery wall (ICAW) in all four cases.
CONCLUSION: CCA exhibits several imaging characteristics, particularly mild contrast enhancement and a tumor size-related T2-weighted signal pattern. Knosp grade 1 was the most frequent parasellar extension pattern. Reduced enhancement of the tumor-adjacent ICAW was observed in four cases with postoperative tumor progression; however, the clinical significance of this finding requires validation in larger cohorts with longer-term follow-up.
引用
- Xing Y, Wang J, Du S, et al. Imaging features of pituitary Crooke cell adenoma: a 13-case series. Neuroradiology. 2026. PMID: 42911244. doi:10.1007/s00234-026-04223-1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。