CT透视引导腰椎硬膜外类固醇注射:学员参与、辐射剂量与手术时间
回顾性单中心研究分析371例CT透视引导腰椎硬膜外类固醇注射,比较仅主治医师操作与学员参与下的患者辐射剂量、手术时间及即刻疼痛缓解。学员参与组总剂量长度乘积更高,但主要由规划CT使用增加和主治医师操作习惯差异驱动;校正后学员参与与总或操作剂量长度乘积无关。学员组手术时间稍长,即刻疼痛缓解相似。
要点
- 学员参与增加总辐射主要源于规划CT使用,而非操作本身辐射。
- 取消规划CT可显著降低总剂量长度乘积,应作为优化重点。
- 学员参与仅轻度延长手术时间,不增加操作相关辐射。
核心结论
- 学员参与CT透视引导腰椎硬膜外类固醇注射与手术时间轻度延长相关,但不增加操作相关辐射。
- 总辐射剂量升高反映规划CT使用增加和主治医师操作差异,而非学员表现。
研究设计与样本
- 回顾性单中心研究纳入2018-2025年371例连续CT透视引导腰椎硬膜外类固醇注射,主治医师单独操作93例,学员在直接监督下操作278例。
- 采用Welch t检验和卡方检验比较患者及手术特征与结局,线性混合效应模型校正年龄、性别、注射入路、规划CT省略及学年,并以监督主治医师为随机截距。
诊断标准与关键数值
- 学员组总剂量长度乘积为53.7 ± 52.0 mGy∙cm,显著高于主治医师组的31.7 ± 40.6 mGy∙cm(p < 0.001)。
- 规划CT剂量长度乘积学员组为37.7 ± 47.3 mGy∙cm,显著高于主治医师组的16.4 ± 32.2 mGy∙cm(p < 0.001)。
- 操作剂量长度乘积学员组为15.6 ± 10.3 mGy∙cm,主治医师组为15.3 ± 11.9 mGy∙cm,无显著差异(p = 0.83)。
- 校正后学员参与与总或操作剂量长度乘积无关,几何均数比均为0.99(95% CI分别为0.81-1.21和0.84-1.17)。
- 学员组手术时间20.0 ± 6.3分钟,长于主治医师组的18.3 ± 4.2分钟(p = 0.005);即刻疼痛缓解评分分别为3.5 ± 2.9和3.4 ± 2.6分,无显著差异(p = 0.81)。
临床应用与阅片要点
- 阅片及报告时应关注规划CT是否省略,因其对总辐射剂量贡献显著。
- 学员参与手术时不必过度担忧操作辐射增加,但需注意手术时间可能轻度延长。
局限性
- 本研究为回顾性单中心设计,可能存在选择偏倚和残留混杂。
- 原文未明确报告其他局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: Compare patient radiation, procedure time, and immediate post-procedural pain relief for CT-fluoroscopy (CTF)-guided lumbar epidural steroid injections (ESIs) performed by attendings alone versus with trainee participation.
MATERIALS AND METHODS: This retrospective single-institution study analyzed 371 consecutive CTF-guided lumbar ESIs (2018-2025) performed by attendings (n = 93) or by trainees under direct attending supervision (n = 278). Patient and procedural characteristics and outcomes were compared using Welch t-tests and chi-squared tests. Total dose length product (DLP) was separated into planning-scan and procedural components. Linear mixed-effects models were adjusted for age, sex, injection approach, planning CT omission, and academic year, with a random intercept for supervising attending.
RESULTS: Total DLP was higher for trainee injections (53.7 ± 52.0 vs 31.7 ± 40.6 mGy∙cm, p < 0.001), driven by the planning CT (37.7 ± 47.3 vs 16.4 ± 32.2 p < 0.001); procedural DLP was similar (15.6 ± 10.3 vs 15.3 ± 11.9 mGy∙cm, p = 0.83). After adjustment, trainee participation was not associated with total or procedural DLP (geometric mean ratio 0.99 for both; 95% CIs 0.81-1.21 and 0.84-1.17). Proceduralist group explained 7% of total DLP variance; planning CT omission and supervising attending added 38% and 10%, respectively. Planning CT omission, practiced by two of seven attendings, declined from 53% of procedures in 2019-2020 to none after 2022. Trainee procedures took longer (20.0 ± 6.3 vs 18.3 ± 4.2, p = 0.005). Immediate pain reduction was similar (3.5 ± 2.9 vs 3.4 ± 2.6 points, p = 0.81).
CONCLUSION: Trainee participation in CTF-guided lumbar ESIs was associated with modestly longer procedures but not increased procedural radiation. Higher total radiation with trainees reflected increasing use of planning CT and attending practice variation rather than trainee performance.
引用
- Shiang T, Wieschhoff GG, Wu JS, et al. CT-fluoroscopy-guided lumbar epidural steroid injections: trainee participation, radiation dose, and procedural time. Skeletal Radiol. 2026. PMID: 42878806. doi:10.1007/s00256-026-05408-8
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。