超声技师执行甲状腺细针穿刺活检项目的长期效果:效率与质量提升
这项单中心回顾性质量改进研究分析了2008至2022年间14127个甲状腺结节的细针穿刺活检,评估结构化超声技师培训项目的长期影响。结果显示,非诊断率从34%降至8.6%,恶性细胞学比例从4.9%升至7.7%,联合Bethesda V/VI诊断从8.9%升至12.1%。晚期阶段,超声技师操作的活检较其他临床医生非诊断率更低(8.6% vs 29%)、恶性检出率更高(7.6% vs 4.5%)。
要点
- 超声技师在放射科医师监督下执行甲状腺FNAB可显著降低非诊断率并提高恶性检出率。
- 结构化培训项目实施后,非诊断率从34%逐步降至8.6%,诊断充分性持续改善。
- 2020年ACR TI-RADS的采用未显著改变标本充分性或恶性率。
局限性
- 单中心回顾性研究,可能存在选择偏倚。
- 非随机分组,同期对照非随机分配。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To evaluate the long-term diagnostic performance and consistency of a dedicated sonographer-performed thyroid FNAB program under radiologist supervision.
MATERIALS AND METHODS: This retrospective quality improvement study (QIRC 23-0591) analyzed consecutive thyroid FNABs performed between 2008 and 2022 at a single academic center. A structured sonographer training program was implemented in 2011. Biopsies were categorized into three periods: pre-implementation (2008-April 2011), early post-implementation (August 2011-2013), and late post-implementation (2014-2022). FNABs performed by other clinicians during the late implementation period served as a contemporaneous control group. Outcomes were assessed at the nodule level using the Bethesda System for Reporting Thyroid Cytopathology. Trend analyses were performed using the Cochran-Armitage test; chi-square tests compared groups.
RESULTS: A total of 14,127 thyroid nodules were biopsied in the radiology (4,382 pre-implementation; 2,561 early post-implementation; 7,184 late post-implementation period). Nondiagnostic rates decreased from 34% (1492/4382) pre-implementation to 21% (534/2561) early post-implementation and 8.6% (617/7184) late post-implementation period (p<.001). Malignant cytology increased from 4.9% to 5.6% to 7.7%, and combined Bethesda V/VI diagnoses increased from 8.9% to 8.5% to 12.1% (both p<.001). During late post-implementation period, sonographer-performed FNABs demonstrated lower nondiagnostic rates (8.6% vs 29%, p<.001) and higher malignant yield (7.6% vs 4.5%, p<.001) compared with other clinicians. Adoption of ACR TI-RADS in 2020 was not associated with significant changes in adequacy or malignancy rates.
CONCLUSIONS: A dedicated sonographer-performed thyroid FNAB program improved diagnostic adequacy and malignancy yield over 11 years, supporting safe delegation of thyroid FNAB to trained physician extenders under radiologist supervision.
引用
- Ghai S, Sawka AM, Perel TK, et al. Enhancing Efficiency and Quality in Thyroid Biopsy: The Long-Term Impact of Implementation of a Program of Dedicated Sonographer-Performed Thyroid Biopsies. J Am Coll Radiol. 2026. PMID: 42933554. doi:10.1016/j.jacr.2026.10.021
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。