文献速递乳腺US

整合式与序贯式AI-CAD在乳腺超声中的前瞻性比较:检查时间、可重复性与诊断性能

Comparison of Integrated Versus Sequential Artificial Intelligence-Based Computer-Aided Diagnosis Systems in Breast Ultrasound: A Prospective Pilot Study on Examination Time, Reproducibility, and Diagnostic Performance.
PubMed 文献 · Acad Radiol · 2026-10-13

这项前瞻性单中心研究比较了整合式与序贯式AI-CAD在乳腺超声中的检查时间、可重复性和诊断性能。整合式AI-CAD检查时间更短、敏感度更高(87.6% vs 76.9%),序贯式特异度更高(90.0% vs 74.2%),两者AUC无差异,可重复性因病灶类型而异。

要点

  • 整合式AI-CAD缩短检查时间且敏感度更高,序贯式特异度更高。
  • 两系统AUC无差异,可重复性因病灶类型不同而有所差异。
  • 阅片时需结合病灶类型理解AI-CAD的敏感度与特异度权衡。

核心结论

  • 整合式与序贯式AI-CAD在乳腺超声中各有优势:整合式检查时间更短、敏感度更高,序贯式特异度更高,可重复性因病灶类型而异。

研究设计与样本

  • 前瞻性单中心研究,纳入2025年2月至3月在乳腺影像中心接受乳腺超声的女性。
  • 检查时间分析纳入97例,可重复性分析纳入145例共215个病灶,诊断性能分析纳入242例。
  • 评估两种实时AI-CAD系统:整合式在扫描时同步检测和诊断,序贯式分开进行检测和诊断评估。
  • 可重复性通过同一病灶两次应用两系统评估,诊断性能以敏感度、特异度和AUC评价。

诊断标准与关键数值

  • 整合式AI-CAD敏感度87.6%,序贯式76.9%,差异有统计学意义(P < .001)。
  • 序贯式AI-CAD特异度90.0%,整合式74.2%,差异有统计学意义(P < .001)。
  • 两系统AUC无差异。
  • 可重复性:两系统首次与第二次采集间几乎完全一致(整合式κ = 0.81,序贯式κ = 0.83)。
  • 首次与第二次采集比较:恶性病灶κ整合式0.92、序贯式0.76;肿块病灶κ整合式0.79、序贯式0.84;非肿块病灶κ整合式1.00、序贯式0.75。

临床应用与阅片要点

  • 追求检查效率和高敏感度时可优先考虑整合式AI-CAD。
  • 需要更高特异度以减少假阳性时,序贯式AI-CAD可能更有优势。
  • 解读AI-CAD结果时应考虑病灶类型对可重复性的影响。

局限性

  • 单中心前瞻性研究,样本量有限。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: To compare integrated and sequential artificial intelligence-based computer-aided diagnosis (AI-CAD) systems in terms of examination time, reproducibility, and diagnostic performance in breast ultrasound (US).

MATERIALS AND METHODS: This prospective single-center study included women who underwent breast US at a breast imaging center between February and March 2025. Two real-time AI-CAD systems were evaluated: an integrated system providing simultaneous lesion detection and diagnosis during scanning, and a sequential system in which lesion detection and diagnostic assessment were performed separately. Examination time was assessed in patients who underwent paired breast US examinations with both AI-CAD systems during the same visit, with randomized examination order. Reproducibility was assessed by applying both systems twice to the same breast lesions. Diagnostic performance was evaluated using sensitivity, specificity, and area under the receiver operating characteristic curve (AUC).

RESULTS: Examination time analysis included 97 patients and showed longer examination time with sequential AI-CAD than with integrated AI-CAD (P < .001), regardless of examination order. Reproducibility analysis included 145 patients with 215 lesions and showed almost perfect agreement between the first and second acquisitions for both systems (integrated vs. sequential: κ = 0.81 vs. 0.83). For the comparison between the first and second acquisitions, κ values for the integrated versus sequential systems were 0.92 versus 0.76 for malignant lesions, 0.79 versus 0.84 for mass lesions, and 1.00 versus 0.75 for nonmass lesions. However, agreement patterns varied across other scan-plane comparisons. Diagnostic performance analysis included 242 patients. Integrated AI-CAD showed higher sensitivity (integrated vs. sequential: 87.6% vs. 76.9%; P < .001), whereas sequential AI-CAD showed higher specificity (integrated vs. sequential: 74.2% vs. 90.0%; P < .001). AUC did not differ between the two systems.

CONCLUSION: Integrated and sequential AI-CAD systems showed complementary strengths in breast US. Integrated AI-CAD favored shorter examination time and higher sensitivity, whereas sequential AI-CAD favored higher specificity, with reproducibility differing according to lesion type.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Ban J, Kim H, Baek SY, et al. Comparison of Integrated Versus Sequential Artificial Intelligence-Based Computer-Aided Diagnosis Systems in Breast Ultrasound: A Prospective Pilot Study on Examination Time, Reproducibility, and Diagnostic Performance. Acad Radiol. 2026. PMID: 42869671. doi:10.1016/j.acra.2026.08.038

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。