VI-RADS质量评分对肌层浸润诊断性能的影响:肿瘤大小与读片者经验的作用
本研究回顾性纳入587例术前接受多参数膀胱MRI的患者,由三名放射科医生独立评估VI-RADS分类和质量评分。结果显示质量评分观察者间一致性良好(k=0.628-0.702),且高质量评分与小肿瘤(<3cm)及经验较少读片者的阳性预测值和准确率提升相关,但在大肿瘤中诊断性能无显著差异。
要点
- VI-RADS质量评分观察者间一致性良好,可作为图像质量控制的可靠工具。
- 在肿瘤<3cm时,高质量图像可提升VI-RADS≥3阈值的阳性预测值和准确率。
- 经验较少的读片者从高质量图像中获益更明显,但需外部验证。
英文原文(摘要)· 点击展开
OBJECTIVES: To evaluate the inter-reader agreement of the Vesical Imaging Reporting and Data System (VI-RADS) quality scoring system and to assess its impact on the diagnostic performance for detecting muscle invasion.
MATERIALS AND METHODS: This retrospective study included 587 patients who underwent multiparametric bladder MRI before surgery. Three radiologists (two specialists and one non-genitourinary radiologist) independently assessed VI-RADS category and quality scores. Inter-reader agreement was evaluated using weighted kappa statistics. Associations between image quality, VI-RADS categorization, and tumor characteristics were analyzed using multivariable models. Diagnostic performance for muscle invasion was assessed at predefined VI-RADS thresholds and compared across quality groups and tumor size subgroups.
RESULTS: A total of 7/587 (1.2%), 284/587 (48.4%), and 296/587 (50.4%) scans were VI-RADS quality score 0, 1, and 2, respectively. Inter-reader agreement for the final quality score was substantial (k = 0.628-0.702). Higher VI-RADS quality scores were associated with increased T2-weighted image VI-RADS scores (odds ratio [OR], 2.95; 95% confidence interval, 1.17-7.43; p = 0.021). In tumors < 3 cm, particularly for the less experienced reader, higher image quality was associated with increased positive predictive value (PPV) and accuracy at the VI-RADS ≥ 3 threshold (PPV: 51.0% vs 22.7%, p = 0.004; accuracy: 81.6% vs 71.7%, p = 0.023). No significant differences in diagnostic performance were observed across VI-RADS thresholds in tumors ≥ 3 cm.
CONCLUSION: The VI-RADS quality scoring system demonstrated good inter-reader agreement. Optimal image quality improved diagnostic performance in small tumors and for the less experienced reader; however, because only one less experienced reader was included, this finding requires external validation.
KEY POINTS: Question Does image quality, assessed by the VI-RADS quality score, influence diagnostic performance of VI-RADS for detecting muscle invasion in bladder cancer? Findings Higher image quality improved PPV and accuracy of VI-RADS, particularly in tumors < 3 cm and for the less experienced reader, while having limited impact in larger tumors. Clinical relevance Ensuring optimal MRI image quality enhances the reliability of VI-RADS interpretation, particularly in small tumors and non-specialized settings, and supports standardized imaging as a prerequisite for accurate bladder cancer staging.
引用
- Joo Y, Cho SW, Tse JR, et al. Impact of VI-RADS quality score on VI-RADS diagnostic performance for muscle invasion: the role of tumor size and reader experience. Eur Radiol. 2026. PMID: 42875622. doi:10.1007/s00330-026-12933-6
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。