文献速递泌尿生殖腹部MR

主动监测期间连续MRI测量前列腺癌病灶大小的多中心观察研究

Measuring prostate cancer lesion size on serial MRI during active surveillance: A multi-centre observational study.
PubMed 文献 · Eur J Radiol · 2026-09-10

结果显示病灶大小测量的观察者间和观察者内变异性较大,尤其对于较大病灶和边界不清的病灶,百分比变化的变异性大于绝对测量值。

要点

  • 前列腺癌病灶MRI测量变异性随病灶增大和边界不清而增加。
  • 边界清晰的小病灶在不同读者和不同时间点间一致性较好。
  • 百分比变化(尤其体积法)比绝对测量值变异性更大。

关键影像表现/征象

  • 变异性随病灶大小增加而增大,边界不清的病灶变异性最大。
  • 较小且边界清晰的病灶在不同读者和不同时间点间一致性更好。
  • 百分比变化的估计值比绝对测量值变异性更大,尤其对于体积测量方法。

临床应用与阅片要点

  • 连续MRI监测前列腺癌病灶时,建议固定阅片医师和测量方法以减少变异。
  • 对较大病灶和边界不清病灶的测量变化应谨慎解读,避免过度判断。
  • 报告百分比变化时需注意其变异性大于绝对测量值,尤其体积法。

局限性

  • 原文未报告敏感度、特异度、AUC等诊断效能指标。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To assess the intra- and inter-reader reliability of measurements of prostate cancer (PCa) lesions on serial multiparametric MRI scans, and to assess how lesion characteristics and measurement methods influence measurements over time in an international two-centre setting.

MATERIALS AND METHODS: Twenty patients with low- or intermediate-risk PCa undergoing active surveillance were included. A total of three MRI scans were evaluated for each patient: one baseline and two serial follow-up scans. Five consultant radiologists from two institutions independently measured the size of the index lesion at each time point by four methods: maximum diameter, biaxial diameters, ellipsoid volume, and planimetry. Measurements were repeated after a four-week 'wash-out' period. Variability was assessed using strip plots and Bland-Altman analysis.

RESULTS: Graphical presentation of inter-reader and intra-reader reliability enabled examination of variability between methods, readers and reads. Variability increased with lesion size and was greatest for lesions with poorly defined margins. Smaller, well-delineated lesions demonstrated greater consistency over time and across readers. Estimates of percentage change showed greater variability than absolute measurements, particularly for volumetric methods. Small differences in the underlying absolute measurements are amplified when expressed relative to baseline values.

CONCLUSION: Serial MRI assessment of PCa lesion size is subject to substantial variability, particularly for larger lesions and lesions with indistinct boundaries. The benefits of consistent readers and measurement methods warrant further confirmation in larger prospective studies to support reliable clinical decision-making during active surveillance.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Pakpoor J, Englman C, Adebusoye B, et al. Measuring prostate cancer lesion size on serial MRI during active surveillance: A multi-centre observational study. Eur J Radiol. 2026. PMID: 42945842. doi:10.1016/j.ejrad.2026.113233

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。