经股静脉经腔静脉肾上腺活检:技术报告与肾上腺活检入路综述
本文报告一例经股静脉经腔静脉途径活检直接毗邻下腔静脉的右肾上腺肿物,该肿物经传统经皮途径无法安全取材。技术采用右股总静脉入路,在荧光和超声引导下将重塑金属引导套管置于下腔静脉内,穿过腔静脉壁部署活检针,锥形束CT确认针位,完成静脉造影排除腔静脉损伤。获得诊断组织且无围手术期并发症,病理示意外性嗜铬细胞瘤。
要点
- 对毗邻下腔静脉、传统经皮途径无法安全取材的右肾上腺肿物,可考虑经股静脉经腔静脉活检。
- 操作需联合荧光和超声引导,锥形束CT确认针位,完成静脉造影排除腔静脉损伤。
- 活检病理可能意外发现嗜铬细胞瘤,需重视术前生化评估。
核心结论
- 经股静脉经腔静脉途径对毗邻下腔静脉的右肾上腺肿物活检技术可行,在严格选择的患者中可获得诊断组织且无围手术期并发症。
研究设计与样本
- 技术报告,描述一例经股静脉经腔静脉途径活检右肾上腺肿物的操作,并附当代肾上腺活检适应证与入路的简要综述。
- 操作采用右股总静脉入路,在荧光和超声引导下将重塑金属引导套管置于下腔静脉内右肾静脉水平邻近病变处,穿过腔静脉壁部署活检针,锥形束CT确认针位,完成静脉造影排除腔静脉损伤。
临床应用与阅片要点
- 对于毗邻下腔静脉、传统经皮途径无法安全取材的右肾上腺肿物,可考虑经股静脉经腔静脉活检。
- 活检病理可能意外发现嗜铬细胞瘤,提示术前应重视生化评估。
- 该技术需在严格选择的患者中由有经验的术者操作,并做好锥形束CT和静脉造影确认。
局限性
- 仅为单例技术报告,经验有限,技术安全性和比较有效性需更大样本评估。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Despite advances in cross-sectional imaging, adrenal biopsy plays a role in a small subset of lesions that remain indeterminate after complete imaging work-up or in which tissue diagnosis would alter management. Anatomic constraints around the adrenal glands can make safe percutaneous access technically challenging. This technical report describes a transfemoral transcaval approach to biopsy of a right adrenal mass directly abutting the inferior vena cava (IVC) that was not safely accessible by conventional percutaneous routes. Additionally, a concise review of contemporary adrenal biopsy indications and access routes is performed. Adapted from transfemoral transcaval liver biopsy, the technique uses right common femoral venous access, positioning of a reshaped metal guide cannula within the IVC at the level of the lesion adjacent to the right renal vein, and deployment of a core biopsy needle across the caval wall under combined fluoroscopic and ultrasound guidance, with cone-beam CT confirmation of needle position and completion venography to exclude caval injury. Diagnostic tissue was obtained without periprocedural complication; histopathology demonstrated an unexpected pheochromocytoma, a finding discussed here in detail due to its implications for pre-procedure biochemical evaluation. This limited experience demonstrates technical feasibility in carefully selected patients. The safety and comparative effectiveness of the technique require evaluation in larger series.
引用
- Rubinov Y, Lubat A, Katz R, et al. Transfemoral transcaval adrenal biopsy: a technical report and review of adrenal biopsy approaches. Abdom Radiol (NY). 2026. PMID: 42965591. doi:10.1007/s00261-026-05849-8
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。