文献速递心血管CT

重建性错位校正在单源光子计数CT中对图像质量、阅片者一致性和诊断信心的影响

Impact of reconstruction-based misalignment correction on image quality, reader agreement, and diagnostic confidence in single-source photon-counting CT.
PubMed 文献 · Eur J Radiol · 2026-10-24

本研究在单源光子计数探测器CT的冠状动脉CT血管成像(CCTA)中,评估重建性错位校正算法对主观图像质量指标的影响。纳入102例患者,由4名不同经验阅片者评估运动伪影、错位伪影和诊断信心。结果表明,错位校正重建显著改善错位伪影和诊断信心,对运动伪影影响较小,且不同经验阅片者间一致性良好。

要点

  • 错位校正重建可显著减少CCTA中的错位伪影并提升诊断信心。
  • 该算法对运动伪影的改善作用有限,阅片时仍需关注运动伪影。
  • 校正后低经验阅片者与最高经验阅片者的一致性有所提高。

关键影像表现/征象

  • 错位校正重建显著改善错位伪影(Δ=0.94,95%CI 0.88-0.99,p<0.01)。
  • 错位校正重建显著提升诊断信心(Δ=0.296,95%CI 0.24-0.36,p<0.01)。
  • 错位校正对运动伪影的改善较温和(Δ=0.065,95%CI 0.008-0.122,p=0.026)。

诊断标准与关键数值

  • 重建类型对图像质量指标评分有显著影响(p=0.031)。
  • 两种重建类型的阅片者间信度均良好(原始数据集ICC=0.713,校正数据集ICC=0.657)。
  • 与最高经验阅片者的一致性在校正后提高(最低经验阅片者精确一致率:43.3% vs 54.1%)。

临床应用与阅片要点

  • 在单源PCD-CT的CCTA重建中可常规应用错位校正算法以减少错位伪影。
  • 错位校正后诊断信心提升,但运动伪影仍需结合心率控制等措施管理。
  • 低经验阅片者使用校正图像可缩小与高经验阅片者的一致性差距。

局限性

  • 单中心研究,样本量有限(102例)。
  • 主观图像质量指标评估可能受阅片者主观因素影响。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Recently, a single-source photon-counting detector (PCD-CT) system with detector settings comparable to the dual-source system has been introduced. Although applicable to coronary CT angiography (CCTA), its lower temporal resolution may lead to more pronounced motion and misalignment artefacts. Image slab misalignment correction algorithm reduces these artefacts; therefore, we aimed to evaluate its effect on subjective image quality metrics on this PCD-CT system.

METHODS: CCTA images were reconstructed with and without using misalignment correction algorithm. Four readers with varying experience evaluated coronary vessels using three image quality metrics: motion, misalignment artefact, and diagnostic confidence. Linear mixed-effect models were used to assess the effects of reconstruction type, image quality metrics, vessels, and readers. To assess reader agreement, intraclass correlation and multiple agreement metrics were used.

RESULTS: 102 patients (53.9% female) were included in the final analysis. The type of reconstruction significantly affected image quality metric scores (p = 0.031). Post-hoc analysis showed that misalignment corrected reconstruction significantly improved misalignment artefacts (Δ = 0.94, 95% CI, 0.88-0.99, p < 0.01) and diagnostic confidence (Δ = 0.296, 95% CI, 0.24-0.36, p < 0.01). Misalignment correction showed a more modest effect on motion artefacts (Δ = 0.065, 95% CI, 0.008-0.122, p = 0.026). Inter-rater reliability was good for both reconstruction types (ICC = 0.713 and ICC = 0.657 for original dataset and corrected dataset). Agreement with the most experienced reader improved using misalignment correction (Exact agreement with the least experienced reader: 43.3% and 54.1%).

CONCLUSION: The correction algorithm reduced misalignment artefacts and enhanced subjective diagnostic confidence on single-source PCD-CT, with benefits observed across readers of varying experience.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Nagy K, Kocsis K, Veréb G, et al. Impact of reconstruction-based misalignment correction on image quality, reader agreement, and diagnostic confidence in single-source photon-counting CT. Eur J Radiol. 2026. PMID: 42950523. doi:10.1016/j.ejrad.2026.113331

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。