VERIDAH:跨成像序列识别椎体枚举异常并自动标注
研究提出 VERIDAH 椎体标注算法,基于多分类头与加权序列预测,在 NAKO MRI 及 CT 队列回顾性评估。在 T2w 矢状位和 CT 上全椎体正确标注受试者比例分别达 98.30% 和 99.18%,并能在任意视野图像中识别胸椎和腰椎枚举异常。
要点
- VERIDAH 在 CT 和 T2w 矢状位均能高比例正确标注全部椎体,优于现有模型。
- 算法可识别胸椎和腰椎枚举异常,CT 上胸椎枚举异常正确识别率 96.30%。
- 适用于任意视野图像,包括有限视野,有助于手术规划等下游任务。
核心结论
- VERIDAH 在 CT 和 T2w 矢状位 MRI 上实现枚举异常鲁棒的椎体标注,并公开算法与脊柱分割模型。
研究设计与样本
- 回顾性研究,使用 NAKO 数据集 MRI 和 CT 队列评估标注性能,统计显著性采用 Wilcoxon 符号秩检验。
诊断标准与关键数值
- T2w TSE 矢状位全椎体正确标注受试者比例 VERIDAH 98.30% vs 现有模型 94.24%,p < 0.01。
- CT 全椎体正确标注受试者比例 VERIDAH 99.18% vs 现有模型 77.26%,p < 0.01。
- T2w 图像胸椎枚举异常正确识别率 87.80%,CT 为 96.30%。
- T2w 图像腰椎枚举异常正确识别率 94.48%,CT 为 97.22%。
临床应用与阅片要点
- 阅片时可借助算法自动标注椎体并提示枚举异常,减少胸腰交界区错标。
- 在有限视野图像中仍可识别椎体水平,便于手术规划等下游任务。
局限性
- 研究为回顾性评估,样本来自 NAKO MRI 和 CT 队列,未报告多中心外部验证结果。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: Although the identification of enumeration anomalies has potential clinical implications for chronic back pain and operation planning, the thoracolumbar junction is poorly assessed and rarely described in clinical reports. Additionally, even though multiple deep-learning-based vertebra labeling algorithms exist, there is a lack of methods to automatically label enumeration anomalies.
MATERIALS AND METHODS: We introduce "Vertebra Identification with Anomaly Handling" (VERIDAH), a novel vertebra labeling algorithm based on multiple classification heads combined with a weighted vertebra sequence prediction algorithm. We use the NAKO dataset for MRI and a CT cohort to retrospectively evaluate the labeling performance by computing how often the model is correct in predicting the vertebra labels, including enumeration anomalies. Statistical significance was assessed using the Wilcoxon signed-rank test.
RESULTS: On 1000 T2w sagittal (mean age 52 ± 11, 52% female) and 365 CT (mean age 74 ± 21, 44% female) images, we show that our approach surpasses existing models on T2w TSE sagittal (98.30% vs. 94.24% of subjects with all vertebrae correctly labeled, p < 0.01) and CT imaging (99.18% vs. 77.26% of subjects with all vertebrae correctly labeled, p < 0.01) and works in arbitrary field-of-view images. VERIDAH correctly labeled the presence of thoracic enumeration anomalies in 87.80% and 96.30% of T2w and CT images, respectively, and lumbar enumeration anomalies in 94.48% and 97.22% for T2w and CT, respectively.
CONCLUSION: VERIDAH offers enumeration anomaly robust vertebra labeling in CT and T2w sagittal imaging and is publicly released along with a spine segmentation model.
KEY POINTS: QuestionAutomatically identifying enumeration anomalies in the spine is important in determining the correct vertebra labels, especially in limited field-of-view imaging. FindingsA carefully designed classifier with multiple classification heads and a sequence predictor provides superior results on large benchmarks, both in CT and MRI. Clinical relevanceThe proposed method identifies vertebra levels even in very limited field-of-view imaging, and correctly predicts enumeration anomalies, making downstream tasks such as surgery planning easier. Its public availability enables studies and applications to take these spinal anomalies into account.
引用
- Möller H, Schön H, Graf R, et al. VERIDAH: solving enumeration anomaly-aware vertebra labeling across imaging sequences. Eur Radiol. 2026. PMID: 42886249. doi:10.1007/s00330-026-12966-x
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。